MétaCan
Menu
Back to cohort
Record W2002162345 · doi:10.1115/1.4001159

The Biomechanical Consequence of Insufficient Femoral Component Lateralization and Exposed Cancellous Bone in Hip Resurfacing Arthroplasty

2010· article· en· W2002162345 on OpenAlexaff
Michael Olsen, Edward T. Davis, Cari Whyne, Rad Zdero, Emil H. Schemitsch

Bibliographic record

VenueJournal of Biomechanical Engineering · 2010
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsHealth Sciences CentreUniversity of TorontoSunnybrook Health Science CentreSt. Michael's Hospital
Fundersnot available
KeywordsCancellous boneImplantFemurValgusFemoral headCortical boneArthroplastyDentistryMedicineMaterials scienceOrthodonticsAnatomyBiomedical engineeringSurgery

Abstract

fetched live from OpenAlex

Insufficient lateralization of the femoral component coupled with exposed reamed cancellous bone has been speculated to predispose to femoral neck fracture. The current study examined the effect of mediolateral implant position and exposed cancellous bone on the strength of the resurfaced proximal femur. Composite femurs were prepared in three configurations: (1) partial, with the implant placed at the native femoral head offset of the femur, partially exposing reamed cancellous bone; (2) proud, with a medialized implant exposing a circumferential ring of cancellous bone; and (3) complete, with a lateralized implant covering all reamed cancellous bone. Specimens were loaded to failure in axial compression. A finite element model was used to further explore the effect of exposed cancellous bone, cement mantle thickness, and relative valgus orientation on the strain distributions in the resurfaced femur. The proud group (2063 N) was significantly weaker than both the partial (2974 N, p=0.004) and complete groups (5899 N, p=0.001) when tested to failure. The partial group was also significantly weaker than the complete group when tested to failure (p=0.001). The finite element model demonstrated increasing levels of strain in the superior reamed cortical-cancellous bone interface with increasing degree of exposed cancellous bone. The condition of the femoral component medialized as the result of a thick cement mantle had the greatest detrimental impact on strain level in the superior reamed cancellous bone while a valgus oriented implant provided a protective effect. This study provides biomechanical evidence that exposed reamed cancellous bone significantly reduces the load-to-failure and increases maximum strains in the resurfaced proximal femur. The perceived benefit of reconstructing the femur to its native geometry may inherently weaken the proximal femur and increase femoral neck fracture risk if the femoral component is not sufficiently lateralized to cover all unsupported reamed cancellous bone. Relative valgus orientation of the implant may help to minimize the risk of neck fracture if reamed cancellous bone remains exposed following implant impaction.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.363
Threshold uncertainty score0.330

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.235
Teacher spread0.223 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2010
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Biomechanical EngineeringSame topicOrthopaedic implants and arthroplastyFrench-language works237,207