MétaCan
Menu
Back to cohort
Record W2002469997 · doi:10.1117/12.807215

Applications of Doppler optical coherence tomography based on zero-crossing detection to flow monitoring inside a stenosis phantom

2008· article· en· W2002469997 on OpenAlexaff
Lionel Carrion, Zhiqiang Xu, R. Maciejko

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2008
Typearticle
Languageen
FieldEngineering
TopicOptical Coherence Tomography Applications
Canadian institutionsPolytechnique Montréal
Fundersnot available
KeywordsOptical coherence tomographyImaging phantomDoppler effectBlood flowOpticsStenosisBiomedical engineeringImage resolutionCoherence (philosophical gambling strategy)Optical tomographyFlow velocityMaterials scienceFlow (mathematics)PhysicsRadiologyMedicineMechanics

Abstract

fetched live from OpenAlex

Most of the time, arterial stenoses caused by atherosclerosis, hardening of the artery walls, or buildup of fatty deposits prevent the blood from flowing normally. Blood flow characteristics in the vicinity of a stenosis are therefore very important since the restriction may accelerate fatty deposits and thus quickly clog the artery. Doppler Optical Coherence Tomography (DOCT) is a biomedical technique that allows simultaneous structural imaging and flow monitoring inside biological tissues and materials with spatial resolution at least one order of magnitude better than ultrasound. This study deals with the application of a Near Infrared DOCT system for imaging and monitoring of liquid flow inside a stenosis phantom inserted in a glass tube. For the measurement of the Doppler frequency, we use a numerical method based on the detection of the zero-crossing points of the OCT signal.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.233
Teacher spread0.219 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicOptical Coherence Tomography ApplicationsFrench-language works237,207