MétaCan
Menu
Back to cohort
Record W2002529663 · doi:10.1007/s11999-013-2878-x

Can Fluoroscopy-based Computer Navigation Improve Entry Point Selection for Intramedullary Nailing of Femur Fractures?

2013· article· en· W2002529663 on OpenAlexaff
Meghan Crookshank, Max R. Edwards, Michael Sellan, Cari Whyne, Emil H. Schemitsch

Bibliographic record

VenueClinical Orthopaedics and Related Research · 2013
Typearticle
Languageen
FieldMedicine
TopicHip and Femur Fractures
Canadian institutionsHealth Sciences CentreUniversity of TorontoSunnybrook Health Science CentreSt. Michael's Hospital
Fundersnot available
KeywordsFluoroscopyMedicineFemurIntramedullary rodGreater trochanterNavigation systemReproducibilityCadaveric spasmComputer visionArtificial intelligenceRadiologyNuclear medicineSurgeryComputer scienceMathematics

Abstract

fetched live from OpenAlex

BACKGROUND: The entry point is crucial to an accurate reduction in femoral nailing. Fluoroscopy-based navigation was developed to aid in reducing femur fractures and selecting entry points. QUESTIONS/PURPOSES: We asked: (1) Can the piriformis fossa (PF) and tip of the greater trochanter (TT) be identified with high reproducibility? (2) What is the range of nonneutral images clinically acceptable for entry point selection? (3) Does navigation improve accuracy and precision of landmarking the TT and PF? And (4) does off-angle fluoroscopy within the acceptable range affect landmark accuracy? METHODS: Three orthopaedic surgeons digitized the PF and TT under direct visualization on 10 cadaveric femurs, quantifying the reproducibility of the targeted PF and TT landmarks. Arcs of acceptable AP and lateral images of each femur were acquired in increments of 5° with a C-arm. An experienced orthopaedic surgeon rejected or accepted images for entry point selection by qualitatively assessing the relative positions and sizes of the greater trochanter, lesser trochanter, and femoral neck. Entry points were identified on each image using fluoroscopy and navigation. Hierarchical linear modeling was used to compare accuracy and precision between navigation and fluoroscopy and the effects of image angle. RESULTS: A 29° average arc of acceptable images was found. Reproducibility of the target landmarks for the PF and TT under direct visualization was excellent. Navigation had similar accuracy to fluoroscopy for PF localization but less for TT. Navigation increased precision compared to fluoroscopy for both PF and TT. Image angle affected accuracy of the PF and TT under fluoroscopy and navigation. CONCLUSIONS: Nonorthogonal images reduce accuracy of PF and TT identification with both navigation and fluoroscopy. Navigation increased precision but decreased accuracy and cannot overcome inaccuracies induced by nonorthogonal images.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.678
Threshold uncertainty score0.779

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.411
Teacher spread0.375 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueClinical Orthopaedics and Related ResearchSame topicHip and Femur FracturesFrench-language works237,207