MétaCan
Menu
Back to cohort
Record W2003459173 · doi:10.1118/1.4815532

WE‐C‐108‐09: Patient‐Specific Monte Carlo Dosimetry for I–125 Prostate Brachytherapy

2013· article· en· W2003459173 on OpenAlexaffabout
Nelson Miksys, Shirin A. Enger, Chang Xu, Éric Vigneault, Luc Beaulieu, RM Thomson

Bibliographic record

VenueMedical Physics · 2013
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsCentre hospitalier universitaire de QuébecUniversité LavalCarleton University
Fundersnot available
KeywordsBrachytherapyDosimetryNuclear medicineMonte Carlo methodStreakingProstateImage-guided radiation therapyMedical imagingMedicineComputer scienceBiomedical engineeringRadiologyRadiation therapyMathematics

Abstract

fetched live from OpenAlex

Purpose: To investigate dose distributions in the prostate and surrounding tissues for I–125 brachytherapy using Monte Carlo (MC) calculations with patient‐specific phantoms derived from CT images. We explore the effectiveness of different techniques to mitigate streaking artifacts due to brachytherapy sources in post‐implant CT images. Methods: Nine patients (45–87 sources) are considered. Streaking artifacts in post‐implant CT images are mitigated using various metallic artifact reduction (MAR) techniques: raw sinogram, fan beam virtual sinogram and 3D median filter. Segmented structures (CTV, rectum and bladder) guide the assignment of tissues (air, muscle, prostate, calcification, average tissue and bone) to develop patient‐specific MC phantoms. The EGSnrc user‐code Brachydose and GEANT4 user‐code ALGEBRA are employed for MC dose calculations using patient‐specific phantoms derived from CT images. Dose distributions generated with patient models derived using different MAR techniques and different calculation methods (MC, TG‐43) are compared directly, and using recommended dose metrics. Results: Application of each MAR technique to patient CT data results in comparable mitigation of streaking artifacts within the treatment volume in CT images. MC calculations based on uncorrected CT data Result in high dose spikes (>200%) in the treatment volume and lower doses (40–70%) in surrounding tissues compared to MC calculations with corrected phantoms. Dose distributions within the prostate from MC simulations using phantoms generated with different MAR techniques are comparable to each other but differ from TG‐43 calculations with significant (10%+) local differences. Conclusion: Mitigation of streaking artifacts in CT images is necessary for patient‐specific MC dose calculations; however, dose distributions and clinical metrics in the target and OAR are insensitive to the particular MAR technique applied. Differences between MC and TG‐43 dose distributions within the target volume and surrounding organs for I‐125 prostate brachytherapy underline the importance of patient‐specific model‐based dose calculations for treatment planning and evaluation. NSERC, CCSRI, The Canada Research Chairs Program

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.979
Threshold uncertainty score0.756

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.220
Teacher spread0.213 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2013
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced X-ray and CT ImagingFrench-language works237,207