MétaCan
Menu
Back to cohort
Record W2003772342 · doi:10.1109/tsg.2015.2392373

Multivariable Droop Control of Synchronous Current Converters in Weak Grids/Microgrids With Decoupled <italic>dq</italic>-Axes Currents

2015· article· en· W2003772342 on OpenAlexaff
Mahdi Ashabani, Yasser Abdel‐Rady I. Mohamed, Mojtaba Mirsalim, Mohammad Aghashabani

Bibliographic record

VenueIEEE Transactions on Smart Grid · 2015
Typearticle
Languageen
FieldEngineering
TopicMicrogrid Control and Optimization
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsVoltage droopControl theory (sociology)MicrogridConvertersController (irrigation)Multivariable calculusPhase-locked loopAutomatic frequency controlVoltage sourceGridSynchronization (alternating current)AC powerComputer scienceEngineeringElectronic engineeringVoltageControl engineeringTopology (electrical circuits)Electrical engineeringControl (management)Mathematics

Abstract

fetched live from OpenAlex

Weak grids/microgrids are gaining considerable attention due to the installation of renewable power generation resources in areas that are remote from load centers. This paper presents a multivariable-droop synchronous current converter control strategy for current management of weak grid/microgrid applications, and offers a systematic and straight-forward design approach using the loop shaping technique. The controller integrates current regulation, management, and limitation that are applicable to weak grids and microgrids (MGs). The multivariable synchronous current converter enables superior decoupling of d- and q-axis currents in weak grids and/or resistive grids where these control variables are highly coupled due to converter operation at large load-angles. Therefore, stable connection of weak (high impedance) resistive MGs to utility grids is feasible. The multivariable droop concept also realizes real power sharing by simultaneous drooping of both frequency and voltage amplitude, which enhances load sharing accuracy in resistive and/or weak grids. Similar to its predecessor, synchronous converters, the controller can eliminate phase-locked loop (PLL) and provides a unified controller, PLL, and load manager in one simple control methodology. This can facilitate grid auto-synchronization, which can improve the stability of voltage source converters in weak grid applications. Also, the controller can participate in the power system frequency, and voltage regulation and control. To evaluate the performance of the controller, several simulations are conducted under various typical scenarios and conditions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.207
Teacher spread0.198 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations86
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueIEEE Transactions on Smart GridSame topicMicrogrid Control and OptimizationFrench-language works237,207