MétaCan
Menu
Back to cohort

Anisotropic bone remodeling of a biomimetic metal-on-metal hip resurfacing implant

2011· article· en· W2004055545 on OpenAlex
Christiane Caouette, Martin Bureau, Pascal‐André Vendittoli, Martin Lavigne, N. Nuño

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueMedical Engineering & Physics · 2011
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsPolytechnique MontréalNational Research Council CanadaUniversité de MontréalHôpital Maisonneuve-RosemontÉcole de Technologie Supérieure
FundersUniversidad de ZaragozaFonds Québécois de la Recherche sur la Nature et les Technologies
KeywordsStress shieldingOsseointegrationHip resurfacingFixation (population genetics)MetaphysisFemoral headBone remodelingMaterials scienceBiomedical engineeringImplantMedicineOrthodonticsSurgery

Abstract

fetched live from OpenAlex

Hip resurfacing (HR) is a highly attractive option for young and active patients. Some surgeons have advocated cementing the metaphyseal stem of the femoral component to improve fixation and survivorship of HR. However, extending component fixation to the metaphysis may promote femoral head strain shielding, which in turn may reduce survival of the femoral component. Replacing the metallic metaphyseal stem by a composite material with bone-matching properties could help to alleviate this phenomenon. This study uses finite element analysis to examine the strain state in the femoral head for three types of implant fixation: an unfixed metallic stem, an osseointegrated biomimetic stem and a cemented metallic stem. Bone remodeling is also simulated to evaluate long-term bone resorption due to strain shielding. Results show that the unfixed stem causes strain shielding in the femoral head, and that cementing the stem increases strain shielding. The biomimetic stem does not eliminate the strain shielding effect, but reduces it significantly versus the metallic cemented version. The current finite element study suggests that an osseointegrated metaphyseal stem made of biomimetic material in hip resurfacing implants could become an interesting alternative when fixation extension is desired.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.634
Threshold uncertainty score0.769

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.235
Teacher spread0.211 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it