MétaCan
Menu
Back to cohort

Anisotropic bone remodeling of a biomimetic metal-on-metal hip resurfacing implant

2011· article· en· W2004055545 on OpenAlexafffund
Christiane Caouette, Martin Bureau, Pascal‐André Vendittoli, Martin Lavigne, N. Nuño

Bibliographic record

VenueMedical Engineering & Physics · 2011
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsPolytechnique MontréalNational Research Council CanadaUniversité de MontréalHôpital Maisonneuve-RosemontÉcole de Technologie Supérieure
FundersUniversidad de ZaragozaFonds Québécois de la Recherche sur la Nature et les Technologies
KeywordsStress shieldingOsseointegrationHip resurfacingFixation (population genetics)MetaphysisFemoral headBone remodelingMaterials scienceBiomedical engineeringImplantMedicineOrthodonticsSurgery

Abstract

fetched live from OpenAlex

Hip resurfacing (HR) is a highly attractive option for young and active patients. Some surgeons have advocated cementing the metaphyseal stem of the femoral component to improve fixation and survivorship of HR. However, extending component fixation to the metaphysis may promote femoral head strain shielding, which in turn may reduce survival of the femoral component. Replacing the metallic metaphyseal stem by a composite material with bone-matching properties could help to alleviate this phenomenon. This study uses finite element analysis to examine the strain state in the femoral head for three types of implant fixation: an unfixed metallic stem, an osseointegrated biomimetic stem and a cemented metallic stem. Bone remodeling is also simulated to evaluate long-term bone resorption due to strain shielding. Results show that the unfixed stem causes strain shielding in the femoral head, and that cementing the stem increases strain shielding. The biomimetic stem does not eliminate the strain shielding effect, but reduces it significantly versus the metallic cemented version. The current finite element study suggests that an osseointegrated metaphyseal stem made of biomimetic material in hip resurfacing implants could become an interesting alternative when fixation extension is desired.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.235
Teacher spread0.211 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2011
Admission routes2
Has abstractyes

Explore more

Same venueMedical Engineering & PhysicsSame topicOrthopaedic implants and arthroplastyFrench-language works237,207