Theoretical and Experimental Investigations of Solar-Thermoelectric Air-Conditioning System for Remote Applications

2015· article· en· W2004667600 on OpenAlexaff
Muath Alomair, Yazeed Alomair, Shohel Mahmud, Hussein A. Abdullah

Bibliographic record

VenueJournal of Thermal Science and Engineering Applications · 2015
Typearticle
Languageen
FieldMaterials Science
TopicAdvanced Thermoelectric Materials and Devices
Canadian institutionsUniversity of Guelph
Fundersnot available
KeywordsAir conditioningCondenser (optics)EvaporatorCoefficient of performanceSolar air conditioningSolar energyActive coolingEnvironmental scienceWater coolingNuclear engineeringMechanical engineeringMeteorologyEngineeringHeat pumpElectrical engineeringHeat exchangerPhysicsOptics

Abstract

fetched live from OpenAlex

In this paper, we have designed and constructed a low cost solar-thermoelectric (TE) air-conditioning system for people in remote areas where electricity is still in short supply. Such system can be potentially used to condition tents and living areas. The proposed solar-powered TE air-conditioning system is based on the principles of Peltier effect to create a finite temperature difference across the condenser and the evaporator of the TE air-conditioning system. The cold side (or the evaporator) of the TE module is used for air-conditioning application; provides cooling to the living space. The thermal energy from the hot side of the module is dumped to the surrounding environment. Using the existing heat transfer and thermodynamics knowledge, an analytical model is developed to predict the performance of the solar-TE air-conditioning system in terms of the hot and cold reservoir temperatures, heat removal rates from the conditioned space, power input, and coefficient of performance (COP). A second analytical model is proposed to predict the cooling down period of the conditioned space as a function of heat removed by air-conditioning system, heat gained through the wall of the conditioned space, and heat generated inside the conditioned space. A detailed system is constructed to predict the performance of solar-TE air-conditioning system experimentally. A conditioned space was constructed to carry out the experimental work. Multiple air-conditioning systems were installed in the conditioned space. The cooling performance of the designed solar-TE air-conditioning system was experimentally tested and verified with the analytical calculation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.017

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0050.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.249
Teacher spread0.240 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Thermal Science and Engineering ApplicationsSame topicAdvanced Thermoelectric Materials and DevicesFrench-language works237,207