MétaCan
Menu
Back to cohort
Record W2004733000 · doi:10.1097/iae.0b013e3182a0e628

FLUID DYNAMICS OF VITRECTOMY PROBES

2013· article· en· W2004733000 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueRetina · 2013
Typearticle
Languageen
FieldMedicine
TopicRetinal and Macular Surgery
Canadian institutionsOptech (Canada)
Fundersnot available
KeywordsVenturi effectPeristaltic pumpAccelerationPeristalsisMechanicsRotodynamic pumpMaterials sciencePhysicsChemistryProgressive cavity pumpVariable displacement pumpMechanical engineeringReciprocating pumpEngineeringThermodynamicsClassical mechanics

Abstract

fetched live from OpenAlex

PURPOSE: To characterize the fluidics of vitreous cutter port in response to aspiration and blade motion using particle image velocimetry techniques. Diverse surgical scenarios and fluid characteristics were replicated. METHODS: The 23-gauge vitreous cutters were immersed in seeded Balanced Salt Solution (BSS) (Alcon, Forth Worth, TX) or egg albumen, and high-speed video was recorded. Fluid velocity, kinetic energy (KE), and acceleration generated by Venturi and peristaltic pumps were measured in aspiration only (200 and 300 mmHg), low-speed vitrectomy (1,600 cuts per minute; 200 mmHg vacuum), and high-speed vitrectomy (3,000 cuts per minute; 300 mmHg vacuum) modes. RESULTS: The Venturi pump generated significantly higher KE than peristaltic pump in BSS (P < 0.0001 for each pair), and aspiration only yielded significantly higher KE. Cutting activation generated significant acceleration (P < 0.001), and the peristaltic pump produced higher positive and negative acceleration peaks (P < 0.001) than the Venturi pump. In egg albumen, the peristaltic pump generated significantly more KE than the Venturi pump (P < 0.001) and perturbed a much wider area. Acceleration was higher for the peristaltic pump in low-speed mode (P < 0.001), whereas in high-speed modality, the Venturi pump produced the highest acceleration peaks (P < 0.001). CONCLUSION: Pump type and blade motion largely influence velocity, KE, and acceleration. In BSS, the Venturi pump induces higher KE and acceleration, although perturbing fluid less diffusely. In egg albumen, the peristaltic pump perturbed a much wider area and induced a higher KE and acceleration than the Venturi pump, even more so at lower cut rates. As a conclusion, particle image velocimetry allowed precise characterization of fluid velocity in response to cutter activation, suggesting a pragmatic approach to surgical scenarios.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.212
Threshold uncertainty score0.544

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.229
Teacher spread0.222 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it