MétaCan
Menu
Back to cohort
Record W2004995977 · doi:10.1088/0967-3334/33/2/259

Wavelet-based motion artifact removal for functional near-infrared spectroscopy

2012· article· en· W2004995977 on OpenAlexafffund
Behnam Molavi, Guy A. Dumont

Bibliographic record

VenuePhysiological Measurement · 2012
Typearticle
Languageen
FieldMedicine
TopicOptical Imaging and Spectroscopy Techniques
Canadian institutionsUniversity of British Columbia
FundersNatural Sciences and Engineering Research Council of CanadaJames S. McDonnell Foundation
KeywordsArtifact (error)WaveletFunctional near-infrared spectroscopyDistortion (music)AttenuationArtificial intelligenceSIGNAL (programming language)Computer scienceSensitivity (control systems)Energy (signal processing)Computer visionMean squared errorPattern recognition (psychology)MathematicsPhysicsOpticsStatisticsEngineeringElectronic engineeringTelecommunications

Abstract

fetched live from OpenAlex

Functional near-infrared spectroscopy (fNIRS) is a powerful tool for monitoring brain functional activities. Due to its non-invasive and non-restraining nature, fNIRS has found broad applications in brain functional studies. However, for fNIRS to work well, it is important to reduce its sensitivity to motion artifacts. We propose a new wavelet-based method for removing motion artifacts from fNIRS signals. The method relies on differences between artifacts and fNIRS signal in terms of duration and amplitude and is specifically designed for spike artifacts. We assume a gaussian distribution for the wavelet coefficients corresponding to the underlying hemodynamic signal in detail levels and identify the artifact coefficients using this distribution. An input parameter controls the intensity of artifact attenuation in trade-off with the level of distortion introduced in the signal. The method only modifies wavelet coefficients in levels adaptively selected based on the degree of contamination with motion artifact. To demonstrate the feasibility of the method, we tested it on experimental fNIRS data collected from three infant subjects. Normalized mean-square error and artifact energy attenuation were used as criteria for performance evaluation. The results show 18.29 and 16.42 dB attenuation in motion artifacts energy for 700 and 830 nm wavelength signals in a total of 29 motion events with no more than -16.7 dB distortion in terms of normalized mean-square error in the artifact-free regions of the signal.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.125
GPT teacher head0.329
Teacher spread0.205 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations614
Published2012
Admission routes2
Has abstractyes

Explore more

Same venuePhysiological MeasurementSame topicOptical Imaging and Spectroscopy TechniquesFrench-language works237,207