MétaCan
Menu
Back to cohort
Record W2005045719 · doi:10.1115/1.2898761

Primary Stability of Cementless Stem in THA Improved With Reduced Interfacial Gaps

2008· article· en· W2005045719 on OpenAlexaff
Young-Bae Park, Hochul Shin, Don-Ok Choi, Carolyne Albert, Yong–San Yoon

Bibliographic record

VenueJournal of Biomechanical Engineering · 2008
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsUniversity of British Columbia
Fundersnot available
KeywordsBroachingFemurMaterials scienceBiomedical engineeringImplantTotal hip replacementStair climbingOrthodonticsSurgeryMedicine

Abstract

fetched live from OpenAlex

Large interfacial gaps between the stem and the bone in cementless total hip arthroplasty may prevent successful bone ingrowth at the sites, and can also be a passage for wear particles. Furthermore, interfacial gaps between the stem and the bone are believed to compromise the primary stability of the implant. Thus, a broaching method that serves to reduce gaps is expected to give clinically preferable results. A modified broach system with a canal guide is introduced to enhance the accuracy of femoral canal shaping in comparison with the conventional broach system for a Versys fibermetal taper stem. The primary stability of the hip systems and the ratios of the stem surface in contact with the femur were measured in a composite femur model. With the conventional method, an average of 67% of the stem surface was shown to be in contact with the bone, and an average stem micromotion/migration of 35 microm 290 microm was observed under 1000 cycles of stair climbing loads. With the modified method, the stem-bone contact ratio significantly increased to 82% (p<0.05), and the average micromotion/migration reduced to 29 microm 49 microm, respectively (p<0.05 for migration). Our finite element models of the hip systems supported that the difference in micromotion could be attributed to the difference in interfacial contact. Interfacial gaps occurring with the conventional broach system were effectively reduced by the proposed method, resulting in improved primary stability.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.075
Threshold uncertainty score0.296

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.224
Teacher spread0.204 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations17
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Biomechanical EngineeringSame topicOrthopaedic implants and arthroplastyFrench-language works237,207