MétaCan
Menu
Back to cohort

Hygroscopic effects on the mobility and mass of cigarette smoke particles

2015· article· en· W2006764457 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
aboutThe title or abstract carries a Canadian signal from the geographic lexicon.

Bibliographic record

VenueJournal of Aerosol Science · 2015
Typearticle
Languageen
FieldEnvironmental Science
TopicWind and Air Flow Studies
Canadian institutionsUniversity of Alberta
FundersBritish American Tobacco
KeywordsDifferential mobility analyzerChemistryRelative humidityParticle (ecology)Particle densityParticle sizeAnalytical Chemistry (journal)Condensation particle counterSaturation (graph theory)Volume (thermodynamics)Particle numberThermodynamicsChromatography

Abstract

fetched live from OpenAlex

The hygroscopic growth of particles, produced from a University of Kentucky 3R4F reference cigarette smoked following Health Canada Intense (HCI) puffing parameters (55 mL puff of 2 s duration, every 30 s), was measured in terms of the electrical mobility diameter and particle mass, using a Hygroscopic Tandem Differential Mobility Analyzer (HTDMA) and Centrifugal Particle Mass Analyzer (CPMA) system. Both the particle mobility diameter and mass growth factors were found to agree with previously determined values and hygroscopicity models. The mobility diameter growth factor of the particles produced from either a University of Kentucky 3R4F or 1R5F reference cigarette, following HCI puffing parameters, were found to be very similar. As the relative humidity (RH) approached saturation, the effects of the initial particle size on the mobility growth factor became more dominant, with larger particles growing proportionally larger than smaller particles. From the measured mobility diameter and mass growth factors, the density growth factor was calculated. This parameter showed that the particle density increased as the sample relative humidity increased. This case is only possible, given that the dried smoke particle density (1109±118 kg/m3) was determined to be greater than the density of water, if the water condensation on the smoke particle dissolves at least a portion of it, resulting in a significant increase in mass with only a small increase volume.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.220
Threshold uncertainty score0.395

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.249
Teacher spread0.226 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it