The physics of computed radiography: Measurements of pulse height spectra of photostimulable phosphor screens using prompt luminescence
Bibliographic record
Abstract
Computed radiography (CR) is a digital technology that employs reusable photostimulable phosphor (PSP) imaging plates (IP) to acquire radiographic images. In CR, the x-ray attenuation pattern of the imaged object is temporarily stored as a latent charge image within the PSP. The latent image is optically readout as photostimulated luminescence (PSL) when the phosphor is subsequently stimulated using a scanning laser. The multiple stages necessary to create a CR image make it difficult to investigate either experimentally or theoretically. In order to examine the performance of the CR system at a fundamental level separate measurements of the processes involved are desirable. Here pulse height spectroscopy is used to study the prompt violet light emission or prompt luminescence (PL) from commercial PSP screens. Since the mechanism by which light escapes from the phosphor is identical for PL and PSL, observations and conclusions based on the pulse height spectra (PHS) of PL are relevant to the understanding of the behavior of the PSL light emission that outputs the radiographic image in CR. The PL PHS of screens of different thickness and optical properties were measured and compared with the PHS of conventional phosphors. A new method for calibration of the PHS in terms of the absolute number of optical photons per x-ray is introduced and compared to previously established methods.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.001 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".