MétaCan
Menu
Back to cohort

Multi‐Center Clinical Experience with a Lumenless, Catheter‐Delivered, Bipolar, Permanent Pacemaker Lead: Implant Safety and Electrical Performance

2006· article· en· W2007126234 on OpenAlexaff
Michael D. Gammage, Randy Lieberman, Raymond Yee, Antonis S. Manolis, Steven J. Compton, César Khazen, Katie Schaaf, KIMBERLY A. OLESON, George H. Crossley

Bibliographic record

VenuePacing and Clinical Electrophysiology · 2006
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsWestern University
Fundersnot available
KeywordsMedicineLead (geology)ImplantStyletSingle CenterProspective cohort studySurgeryCardiology

Abstract

fetched live from OpenAlex

PURPOSE: Reduced lead diameter and reliability can be designed into transvenous permanent pacing leads through use of redundant insulation and removal of the stylet lumen. The model 3830 lead (Medtronic Inc., Minneapolis, MN, USA) is a bipolar, fixed-screw, steroid-eluting, lumenless, 4.1-Fr pacing lead. Implantation can be performed in a variety of right heart sites using a deflectable catheter (Model 10600, Medtronic). Lead performance and safety were studied. METHODS: Two prospective trials of 338 implanted subjects from 56 global sites were conducted. Electrical and safety data were obtained at implant, pre-discharge, and up to 18 months post-implant. Leads were implanted at traditional and alternate right heart sites. RESULTS: The study enrolled 338 subjects (204 males, 70.6 +/- 11.6 years) followed-up for a mean of 10.2 months (range, 0-21.6). Mean P-wave amplitudes ranged from 3.2 mV at 3 months to 2.9 mV at 18 months, while mean atrial pulse width thresholds at 2.5 V ranged from 0.07 ms at 3 months to 0.09 ms at 18 months. Mean R-wave amplitudes ranged from 11.3 mV to 11.1 mV and mean ventricular pulse width thresholds at 2.5 V ranged from 0.10 ms to 0.14 ms. There were 22 ventricular and 12 atrial lead complications within 3 months post-implant. Survival from lead-related complications improved to a clinically acceptable rate in the cohort of patients when revised implant techniques were employed. CONCLUSIONS: With the use of recommended implant techniques, the study results support the electrical efficacy and safety of a catheter-delivered, lumenless lead in traditional or alternate right atrium or right ventricle sites through 18 months post-implant.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.017
Threshold uncertainty score0.794

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.323
Teacher spread0.302 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations86
Published2006
Admission routes1
Has abstractyes

Explore more

Same venuePacing and Clinical ElectrophysiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207