MétaCan
Menu
Back to cohort
Record W2007264728 · doi:10.3109/1354750x.2013.846413

Detection of cobalt in synovial fluid from metal-on-metal hip prosthesis: correlation with the ion haematic level

2013· article· en· W2007264728 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueBiomarkers · 2013
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsSurgical Specialties (Canada)
Fundersnot available
KeywordsCobaltSynovial fluidBody fluidInductively coupled plasma mass spectrometryProsthesisMetalChemistrySynovitisInternal medicineMedicineSurgeryPathologyMass spectrometryChromatographyInorganic chemistry

Abstract

fetched live from OpenAlex

Hip replacement with large metal-on-metal (MoM) coupling has recently been under attention for its metal ions release, inducing several disorders. Since the blood level toxicity threshold for cobalt is known, the aim of this work is to determine whether Co serum and blood levels correlate with the synovial fluid level. Beside this, the synovial fluid Co from patients without prosthesis has also been measured. Co has been determined in 54 samples (32 unilateral MoM and 22 controls) with inductively coupled plasma mass spectrometry in the three matrices. In the prosthesized group, cobalt was significantly higher compared with controls and in the synovial fluid it strongly correlated with whole blood Co (p = 0.847) and serum (p = 0.855). Moreover, the Co levels into whole blood and serum were significantly different. In conclusion, haematic Co concentration correctly reflects Co local level.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.827
Threshold uncertainty score0.296

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.225
Teacher spread0.206 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it