MétaCan
Menu
Back to cohort

In Vitro Organ Culture of the Bovine Intervertebral Disc

2006· article· en· W2007470421 on OpenAlexaff
Cynthia R. Lee, James C. Iatridis, Lucy Poveda, Mauro Alini

Bibliographic record

VenueSpine · 2006
Typearticle
Languageen
FieldMedicine
TopicSpine and Intervertebral Disc Pathology
Canadian institutionsMcGill University
FundersNational Institute of Arthritis and Musculoskeletal and Skin Diseases
KeywordsIntervertebral discGlycosaminoglycanLumbarViability assayIn vitroIntervertebral diskMedicineCell cultureAnatomyAndrologyPathologyBiologyBiochemistry

Abstract

fetched live from OpenAlex

STUDY DESIGN: Whole bovine coccygeal discs were cultured under static load, with or without vertebral endplates (VEPs), and assessed for cell viability, biochemical stability, biosynthetic activity, and biosynthetic responsiveness to changes in mechanical load. OBJECTIVES: To assess the effects of VEPs on biochemical and cellular stability of disc cells during in vitro culture of large disc explants. To determine whether cultured discs could respond to mechanical perturbation. SUMMARY OF BACKGROUND DATA: Previous methods for culturing the intervertebral disc have focused on rabbit and rat discs, but the small size of these discs limits the relevance of these culture systems to the human condition. Bovine coccygeal discs have similar dimensions to the human lumbar disc (i.e., similar size and nominal stresses), but long-term culture of these discs has not been reported. METHODS: Bovine coccygeal discs were harvested with or without VEPs, cultured under static load (5 kg, approximately 0.25 MPa, in situ swelling pressure) for up to 1 week, and evaluated for changes in hydration, glycosaminoglycan content, cell viability, and biosynthetic activity. Additionally, the biochemical and biosynthetic response of discs cultured without VEP to increasing the load to a 20-kg (approximately 1 MPa, the estimated stress in human lumbar disc during heavy lifting) static load for 6 hours was assessed. RESULTS: During the first 24 hours, culturing discs with endplates was moderately better with regards to maintaining in situ anulus hydration and nucleus glycosaminoglycan levels. The endplates, however, obstructed media flow to the disc, resulting in a marked decrease in cell viability after 1 week of culture. Nucleus pulposus cell viability was maintained in discs cultured without endplates, but there was a significant drop in biosynthetic activity within 2 days of culture. Despite this drop, the disc cells in the discs without VEP remained biosynthetically responsive to changes in mechanical loading. CONCLUSIONS: It is possible to maintain cell viability and the biosynthetic responsiveness of large discs for up to 1 week in vitro when the discs are cultured under static load and without VEP.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.604
Threshold uncertainty score0.591

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.260
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations109
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueSpineSame topicSpine and Intervertebral Disc PathologyFrench-language works237,207