MétaCan
Menu
Back to cohort
Record W2007598087 · doi:10.1118/1.1388893

Correcting organ motion artifacts in x‐ray CT systems based on tracking of motion phase by the spatial overlap correlator. II. Experimental study

2001· article· en· W2007598087 on OpenAlexaff
Amar Dhanantwari, Stergios Stergiopoulos, Nikolaos Zamboglou, Dimos Baltas, Hans‐Georg Vogt, Grigoris Karangelis

Bibliographic record

VenueMedical Physics · 2001
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsWestern UniversityDefence Research and Development Canada
FundersEuropean Commission
KeywordsComputer visionIterative reconstructionComputer scienceTracking (education)Artificial intelligenceGatingProjection (relational algebra)Match movingProcess (computing)Image resolutionMotion compensationMotion (physics)AlgorithmMedicine

Abstract

fetched live from OpenAlex

This paper presents the experimental part of an investigation on tracking and eliminating organ motion artifacts in x-ray CT cardiac applications with emphasis on imaging coronary calcification. The system methodology consists of a software implementation of the spatial overlap correlator (SSOC) concept in x-ray CT scanners to track the net amplitude and phase of organ motion during the CT data acquisition process. A coherent sinogram synthesis (CSS) method is then used to identify the repeated phases of a periodic organ motion from the information provided by the SSOC process and hence synthesize a new sinogram with no motion effects. Since the SSOC scheme is capable of tracking cardiac motion, it identifies also the projection points associated with minimum amplitude cardiac motion effects. These points are used to identify a 180 degrees plus the fan angle sinogram for image reconstruction. This leads to a retrospective gating (RG) scheme that is based on the output of the SSOC process. Performance comparison of the proposed methodology with the retrospective ECG gating using real data sets with phantoms and human patients provides a performance assessment of the merits of the proposed methods. Real results demonstrate that the new methodology eliminates the requirement for ECG gating. Moreover, the CSS and the new RG methods do not require breath holding and they can be implemented in x-ray CT scanners to image coronary calcification and the heart's ventricles.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.029
GPT teacher head0.348
Teacher spread0.319 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2001
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207