MétaCan
Menu
Back to cohort
Record W2007690167 · doi:10.1115/1.1993663

Determining Effective Centroid Position in Biomechanical Testing: A Technique for Simplifying Whole Bone Analysis

2005· article· en· W2007690167 on OpenAlexafffund
Gabrielle Whan, R J Runciman, Mark Hurtig

Bibliographic record

VenueJournal of Biomechanical Engineering · 2005
Typearticle
Languageen
FieldMedicine
TopicBone health and osteoporosis research
Canadian institutionsUniversity of Guelph
FundersNatural Sciences and Engineering Research Council of CanadaUniversity of Guelph
KeywordsCentroidElasticity (physics)Strain gaugePosition (finance)Linear elasticityStructural engineeringCross section (physics)Young's modulusMathematicsMaterials scienceFinite element methodGeometryEngineeringComposite materialPhysics

Abstract

fetched live from OpenAlex

BACKGROUND: Whole bone in vitro biomechanical compressive testing can be complicated by three factors: sample asymmetry, heterogeneous material properties, and unknown effective centroid location. METHOD OF APPROACH: The technique presented here facilitates the calculation of effective centroid position, modulus of elasticity and equivalent uniform strain magnitude for a cross section of bone from a simple whole bone compressive test. Simplification of section response to load is achieved through a combination of linear beam and simple planer geometry theory. The technique requires three longitudinal strain gauges be affixed around the test specimen cross section of interest, gauge position need not be determined. Sample loading is then accomplished using a simple four point loading jig. RESULTS: Results of the technique are presented on an object with known elasticity and geometry, an aluminium tube, and seven pairs of equine third metacarpal whole bones. CONCLUSIONS: Average cross section modulus of elasticity, equivalent uniform cross section strain, and effective centroid locations were all predicted to within the range of published values. Employing the testing setup and analysis technique presented in this paper resulted in a significant savings in both implementation complexity and cost over previously available techniques.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.494
Threshold uncertainty score0.666

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0020.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.325
Teacher spread0.303 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2005
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Biomechanical EngineeringSame topicBone health and osteoporosis researchFrench-language works237,207