MétaCan
Menu
Back to cohort
Record W2008855783 · doi:10.1115/1.4027486

Modeling of an Indirect Solar Assisted Heat Pump System for a High Performance Residential House

2014· article· en· W2008855783 on OpenAlexafffundabout
Jenny Chu, Wilkie Choi, Cynthia A. Cruickshank, S. J. Harrison

Bibliographic record

VenueJournal of Solar Energy Engineering · 2014
Typearticle
Languageen
FieldEnergy
TopicGeothermal Energy Systems and Applications
Canadian institutionsQueen's UniversityCarleton University
FundersNatural Sciences and Engineering Research Council of CanadaU.S. Department of Energy
KeywordsTRNSYSHeat pumpThermal energy storageSizingNuclear engineeringSolar energyEnvironmental scienceHybrid heatThermalEngineeringProcess engineeringMechanical engineeringMeteorologyThermodynamicsElectrical engineeringHeat exchangerChemistry

Abstract

fetched live from OpenAlex

The combination of solar thermal and heat pump systems as a single solar assisted heat pump (SAHP) system can significantly reduce residential energy consumption in Canada. As a part of Team Ontario's efforts to develop a high performance house for the U.S. Department of Energy's Solar Decathlon 2013 Competition, an integrated mechanical system (IMS) consisting of a SAHP was investigated. The system was designed to provide domestic hot water (DHW), space-heating, space-cooling, and dehumidification. The system included a cold and a hot thermal storage tanks and a heat pump to move energy from the low temperature reservoir to the hot reservoir. Solar thermal collectors supplied heat to the cold storage and operated at a higher efficiency due to the heat pump reducing the temperature of the collector working fluid. The combination of the heat pump and solar thermal collectors allows more heat to be harvested at a lower temperature, and then boosted to a suitable temperature for domestic use via the heat pump. The IMS and the building's energy loads were modeled using the TRNSYS simulation software. A parametric study was conducted to optimize the control, sizing, and configuration of the system. The simulation results suggested that the investigated system can achieve a free energy ratio (FER) of about 0.583 for the high performance house designed for the Ottawa climate.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.031
Threshold uncertainty score0.061

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0080.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.194
Teacher spread0.184 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations21
Published2014
Admission routes3
Has abstractyes

Explore more

Same venueJournal of Solar Energy EngineeringSame topicGeothermal Energy Systems and ApplicationsFrench-language works237,207