Sub-second high dose rate brachytherapy Monte Carlo dose calculations with<b><tt>bGPUMCD</tt></b>
Bibliographic record
Abstract
PURPOSE: To establish the accuracy and speed of bGPUMCD, a GPU-oriented Monte Carlo code used for high dose rate brachytherapy dose calculations. The first objective is to evaluate the time required for dose calculation when full Monte Carlo generated dose distribution kernels are used for plan optimization. The second objective is to assess the accuracy and speed when recalculating pre-optimized plans, consisting of many dwell positions. METHODS: bGPUMCD is tested with three clinical treatment plans : one prostate case, one breast case, and one rectum case with a shielded applicator. Reference distributions, generated with GEANT4, are used as a basis of comparison. Calculations of full dose distributions of pre-optimized treatment plans as well as single dwell dosimetry are performed. Single source dosimetry, based on TG-43 parameters reproduction, is also presented for the microSelectron V2 (Nucletron, Veenendaal, The Netherlands). RESULTS: In timing experiments, the computation of single dwell position dose kernels takes between 0.25 and 0.5 s. bGPUMCD can compute full dose distributions of previously optimized plans in ∼2 s. bGPUMCD is capable of computing pre-optimized brachytherapy plans within 1% for the prostate case and 2% for the breast and shielded applicator cases, when comparing the dosimetric parameters D90 and V100 of the reference (GEANT4) and bGPUMCD distributions. For all voxels within the target, an absolute average difference of approximately 1% is found for the prostate case, less than 2% for the breast case and less than 2% for the rectum case with shielded applicator. Larger point differences (>5%) are found within bony regions in the prostate case, where bGPUMCD underdoses compared to GEANT4. Single source dosimetry results are mostly within 2% for the radial function and within 1%-4% for the anisotropic function. CONCLUSIONS: bGPUMCD has the potential to allow for fast MC dose calculation in a clinical setting for all phases of HDR treatment planning, from dose kernel calculations for plan optimization to plan recalculation.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".