MétaCan
Menu
Back to cohort
Record W2008930251 · doi:10.1118/1.4730500

Sub-second high dose rate brachytherapy Monte Carlo dose calculations with<b><tt>bGPUMCD</tt></b>

2012· article· en· W2008930251 on OpenAlexafffund
Sami Hissoiny, M DˈAmours, Benoı̂t Ozell, Philippe Després, Luc Beaulieu

Bibliographic record

VenueMedical Physics · 2012
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsCentre hospitalier universitaire de QuébecPolytechnique Montréal
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Cancer Society Research InstituteNvidia
KeywordsMonte Carlo methodDosimetryBrachytherapyRadiation treatment planningNuclear medicineProstate brachytherapyVoxelDwell timeShielded cablePhysicsComputer scienceMathematicsMedicineRadiation therapyStatisticsRadiology

Abstract

fetched live from OpenAlex

PURPOSE: To establish the accuracy and speed of bGPUMCD, a GPU-oriented Monte Carlo code used for high dose rate brachytherapy dose calculations. The first objective is to evaluate the time required for dose calculation when full Monte Carlo generated dose distribution kernels are used for plan optimization. The second objective is to assess the accuracy and speed when recalculating pre-optimized plans, consisting of many dwell positions. METHODS: bGPUMCD is tested with three clinical treatment plans : one prostate case, one breast case, and one rectum case with a shielded applicator. Reference distributions, generated with GEANT4, are used as a basis of comparison. Calculations of full dose distributions of pre-optimized treatment plans as well as single dwell dosimetry are performed. Single source dosimetry, based on TG-43 parameters reproduction, is also presented for the microSelectron V2 (Nucletron, Veenendaal, The Netherlands). RESULTS: In timing experiments, the computation of single dwell position dose kernels takes between 0.25 and 0.5 s. bGPUMCD can compute full dose distributions of previously optimized plans in ∼2 s. bGPUMCD is capable of computing pre-optimized brachytherapy plans within 1% for the prostate case and 2% for the breast and shielded applicator cases, when comparing the dosimetric parameters D90 and V100 of the reference (GEANT4) and bGPUMCD distributions. For all voxels within the target, an absolute average difference of approximately 1% is found for the prostate case, less than 2% for the breast case and less than 2% for the rectum case with shielded applicator. Larger point differences (>5%) are found within bony regions in the prostate case, where bGPUMCD underdoses compared to GEANT4. Single source dosimetry results are mostly within 2% for the radial function and within 1%-4% for the anisotropic function. CONCLUSIONS: bGPUMCD has the potential to allow for fast MC dose calculation in a clinical setting for all phases of HDR treatment planning, from dose kernel calculations for plan optimization to plan recalculation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.008
Threshold uncertainty score0.027

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0080.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.273
Teacher spread0.263 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations21
Published2012
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207