Abstract

fetched live from OpenAlex

The internals in the deaerators of a refinery plant were reported to have experienced a series of failures since their installation in 1985. These failures included development of cracks in the floor plates, damage of supports and breakage of fillet welds. Two possible root causes were initially identified; thermal stresses due to transient conditions and flow induced vibration. The former cause was classified as unlikely since the deaerators were always operating on steady-state conditions. No cyclic operating conditions were imposed on these deaerators. Vibrations however posed as the most likely root cause for the series of failures. The refinery plant inspectors reported that vibrations on the deaerators, although have not been measured, could be physically felt. These vibrations appear to be continuous and increase linearly with load. A finite element analysis was performed to determine the natural frequency of the deaerators. Mode shapes predicted from this calculation show that vibrations could have caused the failures of the internals. Furthermore, the lowest natural frequency of the deaerators appeared to fall within the actual vibration frequency on site (∼20 Hz). Although not confirmed, it is highly suspected that the vibration was excited by the flow (low pressure steam). Several repair options were explored to overcome this problem. These options were concentrated in increasing the stiffness of the steam inlet pipe and the deaerator floor. Finite element assessments demonstrated that the current flexible deaerator floor was the reason for the low natural frequency. An option of introducing reinforcement strips to the bottom side of the floor was identified as the best option to increase the natural frequency of the deaerator and this is expected to overcome the vibration problem. Only one vessel was assessed but the results apply to the other vessels since they are similar in design.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.097
Threshold uncertainty score0.179

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.234
Teacher spread0.206 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2010
Admission routes1
Has abstractyes

Explore more

Same topicNon-Destructive Testing TechniquesFrench-language works237,207