MétaCan
Menu
Back to cohort

Effectiveness of sodium and conductivity kinetic models in predicting end‐dialysis plasma water sodium concentration: Preliminary results of a single‐center experience

2007· article· en· W2010127920 on OpenAlexvenueno aff
Pietro Pozzoni, Salvatore Di Filippo, Giuseppe Pontoriero, Francesco Locatelli

Bibliographic record

VenueHemodialysis International · 2007
Typearticle
Languageen
FieldMedicine
TopicDialysis and Renal Disease Management
Canadian institutionsnot available
Fundersnot available
KeywordsSodiumHemodialysisDialysisKinetic energyChemistryUltrafiltration (renal)ChromatographySurgeryMedicinePhysics

Abstract

fetched live from OpenAlex

The attainment of a neutral sodium balance represents a major objective in hemodialysis patients. It requires that at the end of each dialysis session, total body water volume (V(f)) and total plasma water sodium concentration (Na(pwf)) are constant. Whereas to achieve a constant V(f) it is sufficient that ultrafiltration equals the interdialytic increase in body weight, it is impossible to predict the value of Na(pwf) and calculate the dialysate sodium concentration needed to obtain it without making use of kinetic mathematical models. The effectiveness of both sodium and conductivity kinetic models in predicting Na(pwf) has already been validated in previous clinical studies. However, applying the sodium kinetic model appears to be poorly feasible in the everyday clinical practice, due to the need for blood samples at the start of each dialysis session for the determination of predialysis plasma water sodium concentration. The conductivity kinetic model appears to be more easily applicable, because no blood samples or laboratory tests are needed to determine plasma water conductivity (C(pw)) and ionic dialysance (ID), used in place of plasma water sodium concentration and sodium dialysance, respectively. We applied the 2 models in 69 chronic hemodialysis patients using the Diascan Module for the automatic determination of C(pw) and ID, and using the latter as an estimate of sodium dialysance in the sodium kinetic model. The conductivity kinetic model was shown to be more accurate and precise in predicting Na(pwf) as compared with the sodium kinetic model. Both accuracy and imprecision of the 2 models were not significantly affected by the method used to estimate total body water volume. These findings confirm the conductivity kinetic model as being an effective and easily applicable instrument for the achievement of a neutral sodium balance in chronic hemodialysis patients.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.010
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.033

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.010
Meta-epidemiology (narrow)0.0020.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.269
Teacher spread0.249 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations21
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueHemodialysis InternationalSame topicDialysis and Renal Disease ManagementFrench-language works237,207