Investigation of Reverse Thermosyphoning in an Indirect SDHW System

2010· article· en· W2010200833 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueJournal of Solar Energy Engineering · 2010
Typearticle
Languageen
FieldEngineering
TopicHeat Transfer and Boiling Studies
Canadian institutionsQueen's University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsHeat exchangerThermosiphonThermal energy storageThermalThermal energyMechanicsPressure dropNatural circulationStorage tankEnvironmental scienceNuclear engineeringEnergy storageThermodynamicsMaterials sciencePetroleum engineeringEngineeringPhysics

Abstract

fetched live from OpenAlex

Thermal energy storages with thermosyphon natural convection heat exchangers have been used in solar water heating systems as a means of increasing tank stratification and eliminating the need for a second circulation pump. However, if the storage system is not carefully designed, under adverse pressure conditions, reverse thermosyphoning can result in increased thermal losses from the storage and reduced thermal performance of the system. To investigate this phenomenon, tests were conducted on single tank and multitank thermal storages under controlled laboratory conditions. Energy storage rates and temperature profiles were experimentally measured during charge periods, and the effects of reverse thermosyphoning were quantified. Further objectives of this study were to empirically derive performance characteristics, to develop numerical models to predict the performance of the heat exchanger during reverse thermosyphon operation, and to quantify the relative magnitude of these effects on the energy stored during typical daylong charge periods. Results of this study show that the magnitude of the reverse flow rate depends on the pressure drop characteristics of the heat exchange loop, the system temperatures, and the geometry of the heat exchanger and storage tank. In addition, the results show that in the case of a multitank thermal storage, the carryover of energy to the downstream thermal energy storages depends on the effectiveness of the exchangers used in the system.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.022
Threshold uncertainty score0.455

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.179
Teacher spread0.171 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it