Conduction currents and time to frequency domain transformation for epoxy resin nanocomposites
Bibliographic record
Abstract
This paper concerns several epoxy resin nanocomposites. A DER 332 epoxy resin was chosen as matrix and nanosilica and/or Boron Nitride were chosen as fillers. Conduction currents results obtained using Polarization and Depolarization Current (PDC) tests at room temperature are presented and discussed. Different conduction phenomena were observed following the analysis of the variation of the current density versus the applied electric field. Using the depolarization currents obtained at room temperature under several applied electric fields, time to frequency domain transformation was performed. For this purpose, the currents were fitted using a general time response function based on Curie-von Schweidler law and on the transform proposed by Hamon. The empiric law proposed by Helegeson was also investigated. The time to frequency domain transformed spectra were compared with those obtained by Dielectric Spectroscopy.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.002 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".