MétaCan
Menu
Back to cohort
Record W2011359125 · doi:10.1118/1.4800492

A source model for modulated electron radiation therapy using dynamic jaw movements

2013· article· en· W2011359125 on OpenAlexafffund
Pavlos Papaconstadopoulos, Jan Seuntjens

Bibliographic record

VenueMedical Physics · 2013
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsMcGill UniversityMontreal General Hospital
FundersCanadian Institutes of Health ResearchAlexander S. Onassis Public Benefit Foundation
KeywordsRadiation therapyMedical imagingPhysicsDosimetryMedical physicsComputer scienceMedicineNuclear medicineRadiologyArtificial intelligence

Abstract

fetched live from OpenAlex

PURPOSE: The development of fast and accurate source models (SMs) might be of crucial importance for the future clinical implementation of modulated electron radiation therapy (MERT). In this study, a SM is presented for reconstructing phase-space information of modulated electron beams using a few-leaf electron collimator (FLEC) and the photon jaws. METHODS: During a FLEC-based delivery, two collimation devices (jaws and FLEC) modulate the electron beam characteristics dynamically. The SM separates the beam into a primary and a scattered component. The primary component is derived by a fast Monte Carlo (MC) transport calculation in air using the EGSnrc/BEAMnrc code. The scattered beam is modeled analytically. The accelerator was decomposed into its individual leaf components and the scattered beam was characterized at various levels of the accelerator. Scattered particles are assigned an energy and position by sampling pre-calculated probability distributions. The direction is estimated by geometrical arguments. Particles were assumed to emerge from tunable virtual sources on the side of each collimator leaf. A leaf-hit algorithm was developed to dynamically reject particles that are incident on any collimating leaf. Electron transport in air between the two collimation levels was calculated based on a MC-modified version of the Fermi-Eyges scattering theory. Correlations between direction and position were observed and taken into account at the final collimation level. RESULTS: To validate the model, reconstructed phase-space data were compared with the full accelerator MC phase-space data. The model accurately reproduced the beam characteristics and preserved important correlations. Depth and profile dose distributions in water were derived for square, rectangular, and off-axis field sizes and for a range of clinical energies. Discrepancies in the dose distributions and dose output were within 3% in all cases. CONCLUSIONS: Fast and accurate SMs open the possibility for fast treatment planning in MERT, based on an inverse optimization MC treatment planning scheme.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.295
Teacher spread0.284 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2013
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207