Poster — Thur Eve — 56: Verification of buildup region dose calculation of a treatment planning system

2012· article· en· W2011549462 on OpenAlexaff
Brian Bassey, Narinder Sidhu

Bibliographic record

VenueMedical Physics · 2012
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsBC Cancer AgencyUniversity of Saskatchewan
Fundersnot available
KeywordsPinnacleIonization chamberDosimetryPercentage depth dose curveIonizationNuclear medicineMaterials scienceTrayBlock (permutation group theory)Radiation treatment planningPhysicsGeometryMathematicsIonRadiation therapyMedicineSurgery

Abstract

fetched live from OpenAlex

Buildup region dose calculation of Pinnacle3 (version 9.0), a treatment planning system (TPS) commissioned using cylindrical ionization chamber measurements, have been verified experimentally. Dose values measured using Attix parallel plate ionization chamber were compared with those calculated by Pinnacle3 for a variety of clinical setups involving: 6 MV and 15 MV photon beams, open fields, enhanced dynamic wedges, physical wedges, block tray, 85, 100 and 120 cm source‐to‐surface distances, and square field sizes ranging from 3 × 3 to 30 × 30 cm2. The dose difference (DD) and distance‐to‐agreement (DTA) techniques were used to evaluate the discrepancy between measured and calculated dose values. Based on the criteria of DD less than 2% or DTA less than 2mm, 93.7% of 1,710 dose points for the 6 MV and 96.1% of 2,244 dose points for 15 MV passed. Dose points that failed were mostly for open fields, block tray fields, and physical wedges (15 and 30 degrees) fields; this is attributed to high electron contamination (EC) associated with these fields. The levels of discrepancies between measured and calculated dose values were greatly reduced after remodeling the EC in Pinnacle3 using Attix chamber measurements, an indication that the EC equation in Pinnacle3 may be adequate for modeling EC in the dose buildup region, and the commissioning of a TPS using cylindrical ionization chamber measurements may not provide accurate buildup region dose calculation. Attix chamber measurements were validated using GafChromic EBT2 film; the disagreement was less than 3% for 89.9% of dose values compared.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.013
Threshold uncertainty score0.042

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0130.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.309
Teacher spread0.285 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→