MétaCan
Menu
Back to cohort
Record W2012289987 · doi:10.1117/12.913321

Resolution enhancement of computed radiography images using two orthogonal tilts

2012· article· en· W2012289987 on OpenAlexaff
Steven I. Pollmann, Chris J. D. Norley, Xunhua Yuan, David W. Holdsworth

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2012
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsWestern UniversityRobarts Clinical Trials
Fundersnot available
KeywordsResolution (logic)Computed radiographyRadiographyImage resolutionOpticsComputer scienceComputer visionArtificial intelligencePhysicsImage (mathematics)Image quality

Abstract

fetched live from OpenAlex

Limitations to the spatial resolution of current digital x-ray systems are bounded by the physical characteristics of the xray detector. However, the need to image smaller structures provides motivation to develop high-resolution x-ray detector systems for use with computed radiographic, and tomographic x-ray systems. We report the implementation of a tilted detector technique (TDT) to attain near isotropic resolution enhancement by combining two orthogonal image views, acquired with existing detector hardware tilted at a fixed angle. Images were acquired using a ceiling-mounted x-ray unit (Proteus XR/a, GE Medical Systems, 50kVp, 250mAs). Images were digitized using a Fujifilm Capsula X CR system, from a 35×43cm detector cassette placed on an angulated stand, featuring a 3520×4280 image matrix with an in-plane pixel spacing of 0.1mm. Three images were acquired: two for use with our TDT; and one for comparison, with no detector tilt. Performance was determined by using two line-pair phantoms (Models 07-521 and 07-533, Nuclear Associates) placed orthogonally to each other in the field of view. Custom software corrected for perspective distortion, co-registered and combined the tilted-detector images into a single higher-resolution image. Following unwarping and co-registration, the limiting spatial resolution of an image obtained via the weighted combination of the two orthogonal views (8 lp/mm) is found to be superior to that of a single view acquired with no detector tilt (5 lp/mm). This novel technique shows significant improvement in the spatial resolution of x-ray image acquisitions, using existing x-ray components and detector hardware.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.283
Teacher spread0.264 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207