Implant Degradation and Poor Healing After Endovascular Repair of Abdominal Aortic Aneurysms: An Analysis of Explanted Stent-Grafts

2006· article· en· W2012392938 on OpenAlexaff
Annie Major, Robert Guidoin, Gilles Soulez, Louis Gaboury, Guy Cloutier, Marc Sapoval, Yvan Douville, Guy Dionne, Robert H. Geelkerken, Paul Petrasek, Sophie Lerouge

Bibliographic record

VenueJournal of Endovascular Therapy · 2006
Typearticle
Languageen
FieldMedicine
TopicAortic aneurysm repair treatments
Canadian institutionsUniversité LavalUniversité de MontréalCentre Hospitalier de l’Université de Montréal
Fundersnot available
KeywordsMedicineStentImplantSurgeryAbdominal aortic aneurysmFixation (population genetics)Endovascular aneurysm repairAneurysm

Abstract

fetched live from OpenAlex

PURPOSE: To study explanted stent-grafts to achieve a better understanding of the mechanisms of failure after endovascular treatment of abdominal aortic aneurysms (AAA). METHODS: Twelve stent-grafts were harvested at autopsy (n=3) or during surgical conversion (n=9). Device alterations were investigated by macroscopic examination, radiography, and surface analysis techniques. Healing around the implants was studied via histology and immunohistochemistry, with particular attention to the stent-graft/tissue interface. RESULTS: Degradation was more important with Vanguard stent-grafts (off the market) than with AneuRx and Talent stent-grafts, but rupture of nitinol wires and poor surface finish in Talent stent-grafts raise concern about their corrosion resistance and long-term stability. Poor healing was observed around stent-grafts even after several years of implantation, with absence of vascular smooth muscle cells, fibroblasts, and collagen formation. In addition to the well-known foreign body reaction around the graft, numerous polymorphonuclear cells characteristic of the first step of healing were present in tissues around stent-grafts retrieved at surgical conversion. Factors explaining the lack of tissue organization around stent-grafts are discussed. CONCLUSION: The long-term stability of implants remains a concern and requires more transparency from manufacturers regarding the surface properties of their devices. Lack of neointima formation impairs biological fixation of the implant to the vessel wall, leading to possible endoleaks and migration. New-generation stent-grafts promoting biological fixation should be developed to improve clinical outcomes of this minimally invasive treatment.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.174
Threshold uncertainty score0.851

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.266
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations53
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Endovascular TherapySame topicAortic aneurysm repair treatmentsFrench-language works237,207