MétaCan
Menu
Back to cohort
Record W2013717311 · doi:10.1097/brs.0b013e3182672307

Reliability of Quantitative Magnetic Resonance Imaging Methods in the Assessment of Spinal Canal Stenosis and Cord Compression in Cervical Myelopathy

2012· article· en· W2013717311 on OpenAlexaff
Alina Karpova, Arun Ranganathan, Aileen M. Davis, Abhaya V. Kulkarni, David J. Mikulis, Doron Rabin, Sorin C. Craciunas, Sean R. Smith, Mitchell A. Hansen, K. Joshi George, Michael G. Fehlings

Bibliographic record

VenueSpine · 2012
Typearticle
Languageen
FieldMedicine
TopicCervical and Thoracic Myelopathy
Canadian institutionsSickKids FoundationToronto Western HospitalHospital for Sick ChildrenUniversity Health NetworkUniversity of Toronto
Fundersnot available
KeywordsMedicineIntraclass correlationMagnetic resonance imagingSpinal stenosisStenosisMyelopathyNuclear medicineRadiologySpinal canalSpinal cord compressionCordSpinal canal stenosisSpinal cordSurgeryLumbar

Abstract

fetched live from OpenAlex

In Brief Study Design. Prospective, blinded reliability study of quantitative magnetic resonance imaging (MRI) measures in patients with cervical myelopathy. Objective. To assess the intra- and interobserver reliability of commonly used quantitative MRI measures such as transverse area (TA) of spinal cord, compression ratio (CR), maximum canal compromise (MCC), and maximum spinal cord compression (MSCC). Summary of Background Data. There is no consensus on an optimal quantitative MRI method(s) in assessing canal stenosis and cord compression. Methods. Seven surgeons performed measurements on 17 digital MR images, on 4 separate occasions. The degree of stenosis was evaluated by measuring TA and CR on axial T2, MCC, and MSCC on midsagittal T1- and T2-weighted MRI sequences, respectively. Statistical analyses included repeated-measures analysis of variance and intraclass correlation coefficients (ICCs). Results. The mean ± SD for intraobserver ICC was 0.88 ± 0.1 for MCC, 0.76 ± 0.08 for MSCC, 0.92 ± 0.07 for TA, and 0.82 ± 0.13 for CR. In addition, the interobserver ICC was 0.75 ± 0.04 for MCC, 0.79 ± 0.09 for MSCC, 0.80 ± 0.05 for CR, and 0.86 ± 0.03 for TA. Higher degree of canal compromise (MCC) was associated with lower modified version of Japanese Orthopaedic Association Scale score (P = 0.05). Also, a strong association was found between MSCC and lower modified version of Japanese Orthopaedic Association Scale score, greater number of steps, and longer walking time (P < 0.05). Conclusion. All 4 measurement techniques demonstrated a good to moderately high degree of intra- and interobserver reliability. Highest reliability was noted in the assessment of T2-weighted sequences and axial MRI. Our results show that the measurements of MCC, MSCC, and CR are sufficiently reliable and correlate well with clinical severity of cervical myelopathy. Magnetic resonance images from patients with cervical myelopathy were examined by 7 surgeons to assess the reliability of 4 quantitative magnetic resonance imaging measurements: transverse area, compression ratio, maximum spinal cord, and canal stenosis in ascertaining the severity of cervical myelopathy. All 4 parameters had high to moderate intra- and interobserver reliability.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.187
Threshold uncertainty score0.282

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.414
Teacher spread0.375 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations72
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueSpineSame topicCervical and Thoracic MyelopathyFrench-language works237,207