MétaCan
Menu
Back to cohort
Record W2013996706 · doi:10.1097/opx.0000000000000514

Clinical Performance of Three Silicone Hydrogel Daily Disposable Lenses

2015· article· en· W2013996706 on OpenAlexaff
Jalaiah Varikooty, Marc Schulze, Kathy Dumbleton, Nancy Keir, Craig A. Woods, Desmond Fonn, Lyndon Jones

Bibliographic record

VenueOptometry and Vision Science · 2015
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsOphthalmologyMedicineAsymptomaticContact lensLens (geology)Crossover studySurgeryPathologyOptics

Abstract

fetched live from OpenAlex

PURPOSE: To determine the clinical performance of DAILIES TOTAL1 (DT1), Clariti 1Day (C1D), and 1-DAY ACUVUE TruEye (AVTE) silicone hydrogel daily disposable contact lenses (SiHy DDCLs). METHODS: Eligible participants, subdivided into asymptomatic and symptomatic groups, wore each SiHy DDCLs for three consecutive days. Each participant attended three visits (on day 1 at 0 hours; on days 1 and 3 after 8 hours of wear) per lens type. The order of lens wear was randomized, with at least 1 day washout between lenses. Lens-related performance was evaluated by assessing lens surface deposits, wettability, pre-lens noninvasive tear breakup time, lens movement, and centration; ocular response assessments included conjunctival redness, corneal staining, and conjunctival staining and indentation. RESULTS: Fifty-one asymptomatic and 53 symptomatic participants completed the study. For all visits, the mean noninvasive tear breakup time was about 1 second longer with DT1 than with C1D and AVTE (p < 0.01). Overall, the wettability of all three lenses was good; however, DT1 was graded marginally better than the other lenses (both p < 0.01). On day 3, eyes wearing AVTE had significantly more dehydration-induced corneal staining compared with DT1 (AVTE, 24%; DT1, 11%; p < 0.01). After 8 hours, conjunctival staining was different between lenses (greatest with C1D and least with DT1; all p < 0.01). Conjunctival indentation was more prevalent with the C1D lenses (n = 70) compared with DT1 (n = 1; p < 0.01) and AVTE (n = 11; p < 0.01). There were no differences between asymptomatic and symptomatic lens wearers for any of the clinical parameters (all p > 0.05). CONCLUSIONS: Each of the three SiHy DDCLs performed well. Noninvasive tear breakup time was longest and wettability was greater with DT1. C1D had the most conjunctival staining conjunctival indentation. There was no difference between asymptomatic and symptomatic wearers with regard to ocular response and contact lens-related parameters. These results suggest that SiHy DDCLs may be an excellent contact lens modality for the symptomatic patient.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.005
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.042
GPT teacher head0.430
Teacher spread0.388 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations46
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueOptometry and Vision ScienceSame topicOcular Surface and Contact LensFrench-language works237,207