MétaCan
Menu
Back to cohort
Record W2014185324 · doi:10.1021/es102767g

Sources, Emissions, and Fate of Polybrominated Diphenyl Ethers and Polychlorinated Biphenyls Indoors in Toronto, Canada

2011· article· en· W2014185324 on OpenAlexaffabout
Xianming Zhang, Miriam L. Diamond, Matthew Robson, Stuart Harrad

Bibliographic record

VenueEnvironmental Science & Technology · 2011
Typearticle
Languageen
FieldEnvironmental Science
TopicToxic Organic Pollutants Impact
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsPolybrominated diphenyl ethersCongenerEnvironmental chemistryEnvironmental sciencePersistent organic pollutantChemistryPolybrominated BiphenylsEnvironmental engineeringPollutantOrganic chemistry

Abstract

fetched live from OpenAlex

Indoor air concentrations of polybrominated diphenyl ethers (PBDEs) and polychlorinated biphenyls (PCBs) measured in 20 locations in Toronto ranged 0.008-16 ng·m(-3) (median 0.071 ng·m(-3)) and 0.8-130.5 ng·m(-3) (median 8.5 ng·m(-3)), respectively. PBDE and PCB air concentrations in homes tended to be lower than that in offices. Principal component analysis of congener profiles suggested that electrical equipment was the main source of PBDEs in locations with higher concentrations, whereas PUF furniture and carpets were likely sources to locations with lower concentrations. PCB profiles in indoor air were similar to Aroclors 1248, 1232, and 1242 and some exterior building sealant profiles. Individual PBDE and PCB congener concentrations in air were positively correlated with colocated dust concentrations, but total PBDE and total PCB concentrations in these two media were not correlated. Equilibrium partitioning between air and dust was further examined using log-transformed dust/air concentration ratios for which lower brominated PBDEs and all PCBs were correlated with K(OA). This was not the case for higher brominated BDEs for which the measured ratios fell below those based on K(OA) suggesting the air-dust partitioning process could be kinetically limited. Total emissions of PBDEs and PCBs to one intensively studied office were estimated at 87-550 ng·h(-1) and 280-5870 ng·h(-1), respectively, using the Multimedia Indoor Model of Zhang et al. Depending on the air exchange rate, up to 90% of total losses from the office could be to outdoors by means of ventilation. These results support the hypotheses that dominant sources of PBDEs differ according to location and that indoor concentrations and hence emissions contribute to outdoor concentrations due to higher indoor than outdoor concentrations along with estimates of losses via ventilation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesScience and technology studies, Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.304
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.004
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.005
GPT teacher head0.196
Teacher spread0.190 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations148
Published2011
Admission routes2
Has abstractyes

Explore more

Same venueEnvironmental Science & TechnologySame topicToxic Organic Pollutants ImpactFrench-language works237,207