MétaCan
Menu
Back to cohort
Record W2014328105 · doi:10.1118/1.3416937

Registration between ultrasound and fluoroscopy or CT in prostate brachytherapy

2010· article· en· W2014328105 on OpenAlexafffund
Pascal Fallavollita, Zahra Karim Aghaloo, Everette C. Burdette, Daniel Y. Song, Purang Abolmaesumi, Gábor Fichtinger

Bibliographic record

VenueMedical Physics · 2010
Typearticle
Languageen
FieldMedicine
TopicProstate Cancer Diagnosis and Treatment
Canadian institutionsUniversity of British ColumbiaMcGill UniversityQueen's University
FundersNatural Sciences and Engineering Research Council of CanadaQueen's University
KeywordsFluoroscopyFiducial markerImage registrationImaging phantomBrachytherapyUltrasoundMedicineGround truthDosimetryNuclear medicineMedical imagingRadiologyComputer visionComputer scienceRadiation therapyImage (mathematics)

Abstract

fetched live from OpenAlex

PURPOSE: In prostate brachytherapy, transrectal ultrasound (TRUS) is used to visualize the anatomy, while implanted seeds can be visualized by fluoroscopy. Intraoperative dosimetry optimization is possible using a combination of TRUS and fluoroscopy, but requires localization of the fluoroscopy-derived seed cloud, relative to the anatomy as seen on TRUS. The authors propose to develop a method of registration of TRUS images and the implants reconstructed from fluoroscopy. METHODS: A phantom was implanted with 48 seeds then imaged with TRUS and CT. Seeds were reconstructed from CT yielding a cloud of seeds. Fiducial-based ground-truth registration was established between the TRUS and CT. TRUS images are filtered, compounded, and registered to the reconstructed implants by using an intensity-based metric. The authors evaluated a volume-to-volume and point-to-volume registration scheme. In total, seven TRUS filtering techniques and three image similarity metrics were analyzed. The method was also tested on human subject data captured from a brachytherapy procedure. RESULTS: For volume-to-volume registration, noise reduction filter and normalized correlation metrics yielded the best result: An average of 0.54 +/- 0.11 mm seed localization error relative to ground truth. For point-to-volume registration, noise reduction combined with beam profile filter and mean squares metrics yielded the best result: An average of 0.38 +/- 0.19 mm seed localization error relative to the ground truth. In human patient data, C-arm fluoroscopy images showed 81 radioactive seeds implanted inside the prostate. A qualitative analysis showed clinically correct agreement between the seeds visible in TRUS and reconstructed from intraoperative fluoroscopy imaging. The measured registration error compared to the manually selected seed locations by the clinician was 2.86 +/- 1.26 mm. CONCLUSIONS: Fully automated registration between TRUS and the reconstructed seeds performed well in ground-truth phantom experiments and qualitative observation showed adequate performance on early clinical patient data.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.210
Threshold uncertainty score0.328

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.317
Teacher spread0.297 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2010
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicProstate Cancer Diagnosis and TreatmentFrench-language works237,207