MétaCan
Menu
Back to cohort
Record W2014364574 · doi:10.1055/s-0033-1345037

Accuracy of Intraoperative Computed Tomography–Based Navigation for Placement of Percutaneous Pedicle Screws

2013· article· en· W2014364574 on OpenAlexaff
Jason C. Eck, Jeffrey K. Lange, John Street, Anthony Lapinsky, Christian P. DiPaola

Bibliographic record

VenueGlobal Spine Journal · 2013
Typearticle
Languageen
FieldMedicine
TopicSpinal Fractures and Fixation Techniques
Canadian institutionsUniversity of British Columbia
Fundersnot available
KeywordsCadaveric spasmMedicinePercutaneousLumbarCadaverPerioperativeSurgeryRadiology

Abstract

fetched live from OpenAlex

MISS techniques have gained recent popularity. The proposed benefits of these techniques include reduced tissue trauma, reduced blood loss, less perioperative pain, and a quicker recovery and return to normal activities. The purpose of this study was to evaluate the accuracy of intraoperative computed tomography (CT)-based navigation for placement of percutaneous pedicle screws in a cadaveric model. Outcome measures included accuracy of screw placement. Two cadaveric specimens were utilized. CT images were obtained using an O-Arm (Medtronic, Memphis, Tennessee, United States) and were coupled to the Stealth navigation system (Medtronic). Computer navigation was used for placement of percutaneous pedicle screws. Screws were placed bilaterally from T5 to S1. Postinsertion CT scans were obtained. Pedicle breach was assessed and classified (I: none, II: < 2 mm, III: 2 to 4 mm, or IV: > 4 mm) with direction of breach. Thirty thoracic screws were placed with 3 (10%) medial breaches and 17 (56.7%) lateral breaches (grade III). Of 20 lumbar screws there were 0 medial breaches and 2 (10%) lateral breaches (1 grade III, 1 grade IV). Four sacral screws were placed without breaches. The real-time computer-aided navigation tool ("simulated screw") was limited in identifying a breach. Manipulation of the surgeon's hand or driver could change the orientation of the navigation tool without changing the screw trajectory. CT-based navigation for percutaneous pedicle screw placement appears safe for the lumbar spine. Lateral thoracic breaches appeared commonly but were not felt to be clinically significant. The 10% rate of medial thoracic breach was concerning, but definitive conclusions could not be made due to the small sample size.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.009
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.009
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.316
Teacher spread0.303 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueGlobal Spine JournalSame topicSpinal Fractures and Fixation TechniquesFrench-language works237,207