MétaCan
Menu
Back to cohort
Record W2014610957 · doi:10.1017/s0317167100004455

The Reliability of Ultrasound Measurements of Carotid Stenosis Compared to MRA and DSA

2005· article· en· W2014610957 on OpenAlexaffvenue
Colin Honish, Venkatraman Sadanand, D. Fladeland, Vance Chow, Fahrad Pirouzmand

Bibliographic record

VenueCanadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · 2005
Typearticle
Languageen
FieldMedicine
TopicCerebrovascular and Carotid Artery Diseases
Canadian institutionsUniversity of TorontoSunnybrook Health Science CentreUniversity of SaskatchewanRoyal University Hospital
Fundersnot available
KeywordsMedicineDigital subtraction angiographyStenosisMagnetic resonance angiographyRadiologyKappaMagnetic resonance imagingGold standard (test)Stroke (engine)UltrasoundNuclear medicineAngiographyMathematics

Abstract

fetched live from OpenAlex

OBJECTIVE: Carotid ultrasound (US) is a screening test for patients with transient ischemic attacks (TIAs) or stroke who then undergo Digital Subtraction Angiogram (DSA) or Magnetic Resonance Angiography (MRA). Gold standard DSA is invasive with inherent risks and costs. MRA is an evolving technology. This study compares reliability of MRA and US modes with DSA in determining degree of internal carotid artery stenosis. METHODS: A five year retrospective analysis of 140 carotid arteries from patients who had carotid US and DSA, and possibly Magnetic Resonance Angiography was undertaken. Recorded US parameters were peak systolic velocity (PSV), end diastolic velocity (EDV), and ICA/CCA peak systolic velocity ratio. The MRA and DSA parameters used NASCET technique for measuring stenosis. Statistical analysis included ROC curves and Kappa computation. RESULTS: US grading of carotid stenosis can be made more reliable by choosing appropriate parameters. The best combination of sensitivity and specificity for stenosis > 70% in our hospital was seen at PSV > 173 cm/s (sensitivity 0.87, specificity 0.8, Positive Predictive Value (PPV) 0.70, Negative Predictive Value (NPV) 0.93, kappa 0.64 and weighted kappa 0.71). MRA kappa was 0.78, (sensitivity 0.75, specificity 1.0, PPV 1.0, NPV 0.85). CONCLUSIONS: US parameters should be validated in each centre. At best, US can only approximate the accuracy of DSA, probably due to inherent limitations of this modality. Magnetic Resonance Angiography has a perfect specificity and PPV but this technique needs to be standardized. Simultaneous use of MRA and US for screening increases sensitivity to over 0.9 without compromising specificity in > 70% stenosis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.017
metaresearch head score (Gemma)0.079
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.017
Threshold uncertainty score0.087

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0170.079
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0030.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.271
Teacher spread0.233 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations16
Published2005
Admission routes2
Has abstractyes

Explore more

Same venueCanadian Journal of Neurological Sciences / Journal Canadien des Sciences NeurologiquesSame topicCerebrovascular and Carotid Artery DiseasesFrench-language works237,207