MétaCan
Menu
← Back to cohort
Record W2015518476 · doi:10.1118/1.4815313

MO‐F‐144‐03: Real‐Time Guidance and Planning in Breast High Dose Rate Brachytherapy Using 3D Ultrasound

2013· article· en· W2015518476 on OpenAlexaff
Éric Poulin, Lori Gardi, Aaron Fenster, Jean Pouliot, Luc Beaulieu

Bibliographic record

VenueMedical Physics · 2013
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversité LavalRobarts Clinical TrialsCentre hospitalier universitaire de Québec
Fundersnot available
KeywordsBrachytherapyImaging phantom3D ultrasoundRadiation treatment planningUltrasoundNuclear medicineScannerMedicineComputer scienceDosimetryRadiologyArtificial intelligenceRadiation therapy

Abstract

fetched live from OpenAlex

Purpose: In breast interstitial high dose rate (HDR) brachytherapy, the number and positions of the catheters are usually chosen manually using a preimplant CT scan. In this work, we present an innovative approach for real‐time 3D ultrasound (3DUS) planning in breast HDR brachytherapy. Methods: The end‐to‐end procedure was realized with a computer controlled robotic 3DUS system for breast brachytherapy so that both planning and guidance are possible. The scanner is mounted on the Kuske template (Nucletron, Veneendal, The Netherlands) so that the scan direction is longitudinal to the catheter axis. Software modules were developed for the acquisition and reconstruction of ultrasound images. A semi‐automatic segmentation algorithm and a needle reconstruction algorithm were integrated into the software to segment the planning target volume and reconstruct the catheter. A Centroidal Voronoi Tessellations (CVT) algorithm, in conjunction with IPSA, was used for catheter number and position optimization. The procedure was tested with 9 catheters in an agarose‐based phantom with a hypo‐echoic mass. Results: The 3DUS acquisition time is less than 7s and the catheter optimization algorithm can obtain 10 complete treatments plans, with the corresponding dosimetric indices, in 90s. The catheter optimization algorithm was shown to reduce the number of catheters to 12 without reducing the quality of the treatment. Breast PTV V100 and dose homogeneity index (DHI) calculated after the procedure were compared to the value obtained from the optimal plan calculated with the CVT algorithm. Both dosimetric indexes were still within RTOG guidelines after the procedure. However, the PTV V100 is smaller after the procedure due to the template‐based implantation. Isodoses are comparable. Conclusion: We have devised a simple, fast and efficient method for real‐time 3DUS guidance of breast HDR brachytherapy. This approach could be coupled with personalized 3D‐printed or robotic template to further optimize this brachytherapy procedure. Funding support: CIHR and NSERC

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.280
Teacher spread0.271 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→