MétaCan
Menu
← Back to cohort
Record W2015749957 · doi:10.1016/j.brachy.2011.07.007

Semiautomatic segmentation for prostate brachytherapy: Dosimetric evaluation

2011· article· en· W2015749957 on OpenAlexafffund
S. Sara Mahdavi, Ingrid Spadinger, Nick Chng, Septimiu E. Salcudean, William Morris

Bibliographic record

VenueBrachytherapy · 2011
Typearticle
Languageen
FieldMedicine
TopicProstate Cancer Diagnosis and Treatment
Canadian institutionsBC Cancer AgencyUniversity of British Columbia
FundersBC Cancer Agency
KeywordsMedicineSegmentationContext (archaeology)InitializationRadiation treatment planningNuclear medicineComputer visionConsistency (knowledge bases)BrachytherapyArtificial intelligenceMedical physicsComputer scienceRadiation therapyRadiology

Abstract

fetched live from OpenAlex

PURPOSE: To demonstrate that manual prostate segmentation in transrectal ultrasound images can be replaced with semiautomatic segmentation. METHODS AND MATERIALS: Semiautomatic segmentation using a tapered ellipsoid model was applied to transrectal ultrasound images. Region-based volumetric evaluation was performed between original and physician-reviewed semiautomatic contours. For dosimetric assessment, treatment plans generated on semiautomatic contours were overlaid on physician-reviewed semiautomatic contours and dose parameters were computed. To establish a threshold for the acceptable amount of dosimetric degradation below which the adoption of semiautomatic planning is unacceptable, the range of variability in dosimetric quality attributed to manual variability was obtained and compared with that of semiautomatic contours. RESULTS: An average volume error (1-Dice similarity coefficient) of less than 7% between semiautomatic and manual volumes (140 cases) was obtained. The difference between the mean V(100) of plans created for semiautomatic contours then overlaid on physician-reviewed semiautomatic contours and the original V(100) values, that is, before overlaying on the physician-reviewed contours (41 cases) was lower than 5%. An average total duration of 2-4min, which includes algorithm initialization, 11.67±3.57s algorithm time, and contour modification is required per case. This algorithm is being used at the British Columbia Cancer Agency and to this date has been applied for the treatment of more than 600 patients. CONCLUSIONS: In terms of volumetric and dosimetric accuracy, the proposed algorithm is a suitable replacement for manual segmentation in the context of our planning technique. The benefits are shorter segmentation times; greater consistency; less reliance on user experience; and smooth, symmetric contours.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.012
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.018

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.012
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.066
GPT teacher head0.337
Teacher spread0.270 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2011
Admission routes2
Has abstractyes

Explore more

Same venueBrachytherapy→Same topicProstate Cancer Diagnosis and Treatment→French-language works237,207→