MétaCan
Menu
Back to cohort
Record W2015798924 · doi:10.1021/ac0481708

Atmospheric Pressure Ionization in a Miniature Mass Spectrometer

2005· article· en· W2015798924 on OpenAlexfundno aff
Brian C. Laughlin, Christopher C. Mulligan, R. Graham Cooks

Bibliographic record

VenueAnalytical Chemistry · 2005
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsnot available
FundersMcMaster UniversityAgilent Technologies
KeywordsChemistryMass spectrometryDesorption electrospray ionizationAnalytical Chemistry (journal)Ion sourceIonizationIon trapAtmospheric pressureAmbient ionizationChemical ionizationIonChromatographyPhysics

Abstract

fetched live from OpenAlex

A miniature cylindrical ion trap mass spectrometer featuring an atmospheric pressure interface allowing atmospheric pressure chemical ionization and electrospray ionization is described together with its analytical performance characteristics. The vacuum system, ion optics, mass analyzer, control electronics system, and detection system have all been designed and built in-house. The design is based upon a three-stage, differentially pumped vacuum system with the instrument capable of being interfaced to many types of atmospheric pressure ionization sources. Ions are transferred through home-built ion optics, and instrument control is achieved through custom-designed electronics and LabView control software. Corona discharge ionization and electrospray ionization sources are implemented and used to allow the analysis of both gaseous- and solution-phase samples during the characterization of the instrument. An upper mass/charge limit of approximately 450 Th with unit resolution was achieved using a 2.5-mm-internal radius cylindrical ion trap as the mass analyzer. The specificity of the instrument can be increased by employing the MS/MS capabilities of the ion trap and has been demonstrated for nitrobenzene. Limits of detection for the trace analysis in air of the chemical warfare agent simulant methyl salicylate (1.24 ppb) and for nitrobenzene (629 pptr) are achieved. The dynamic range of the instrument is currently limited to approximately 2 orders of magnitude by saturation of the detection electronics. Isolation and collision-induced dissociation efficiencies in MS/MS experiments both greater than 50% are reported. Electrospray/nanospray data are presented on solutions including 100 microM (D,L)-arginine, 10 microM (-)-ephedrine, and 10 microM lomefloxacin.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.006
Threshold uncertainty score0.020

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0060.004

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.241
Teacher spread0.235 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations66
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueAnalytical ChemistrySame topicMass Spectrometry Techniques and ApplicationsFrench-language works237,207