Bibliographic record
Abstract
Biological calibration of the Hewlett-Packard electronic spirometer against a Stead-Wells 13.5-litre spirometer shows a good concordance for forced vital capacity (FVC; systematic error 0% in women, 1% in men, probable error 4% in both sexes). However, the electronic device underestimates both 1-second forced expiratory volume (FEV1.0) and maximum mid-expiratory flow rate (MMEF) by 8-10%. This bias is unlikely to reflect technical problems of calibration, voltage drift, condensation of moisture or an inappropriate BTPS calibration; possible causes are a non-linearity in the pneumotachograph response characteristics, a lower resistance to expiration in the electronic device, and greater feedback to the subject and observer with the traditional spirometer. Given reports that similar discrepancies arise with other electronic spirometers, care should be taken in overinterpreting data obtained by such devices.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.044 | 0.078 |
| Meta-epidemiology (narrow) | 0.001 | 0.001 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.001 | 0.002 |
| Scholarly communication | 0.001 | 0.002 |
| Open science | 0.002 | 0.001 |
| Research integrity | 0.003 | 0.001 |
| Insufficient payload (model declined to judge) | 0.003 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".