MétaCan
Menu
Back to cohort
Record W2015812941 · doi:10.1159/000194909

Accuracy of an Electronic Spirometer – A Field Trial

2009· article· en· W2015812941 on OpenAlexaff
Andris Rode, Roy J. Shephard

Bibliographic record

VenueRespiration · 2009
Typearticle
Languageen
FieldMedicine
TopicChronic Obstructive Pulmonary Disease (COPD) Research
Canadian institutionsUniversity of Toronto
Fundersnot available
KeywordsSpirometerMedicineVital capacityCalibrationSpirometryPhysical therapyStatisticsInternal medicineAsthmaLung functionMathematics

Abstract

fetched live from OpenAlex

Biological calibration of the Hewlett-Packard electronic spirometer against a Stead-Wells 13.5-litre spirometer shows a good concordance for forced vital capacity (FVC; systematic error 0% in women, 1% in men, probable error 4% in both sexes). However, the electronic device underestimates both 1-second forced expiratory volume (FEV1.0) and maximum mid-expiratory flow rate (MMEF) by 8-10%. This bias is unlikely to reflect technical problems of calibration, voltage drift, condensation of moisture or an inappropriate BTPS calibration; possible causes are a non-linearity in the pneumotachograph response characteristics, a lower resistance to expiration in the electronic device, and greater feedback to the subject and observer with the traditional spirometer. Given reports that similar discrepancies arise with other electronic spirometers, care should be taken in overinterpreting data obtained by such devices.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.044
metaresearch head score (Gemma)0.078
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.044
Threshold uncertainty score0.232

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0440.078
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.002
Scholarly communication0.0010.002
Open science0.0020.001
Research integrity0.0030.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.349
Teacher spread0.323 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueRespirationSame topicChronic Obstructive Pulmonary Disease (COPD) ResearchFrench-language works237,207