MétaCan
Menu
Back to cohort
Record W2016688044 · doi:10.1139/cjc-2014-0460

Determination of phenazopyridine in biological fluids using electromembrane extraction followed by high-performance liquid chromatography

2015· article· en· W2016688044 on OpenAlexvenueno aff
Lida Fotouhi, Yadollah Yamini, Razieh Hosseini, Maryam Rezazadeh

Bibliographic record

VenueCanadian Journal of Chemistry · 2015
Typearticle
Languageen
FieldChemistry
TopicAnalytical chemistry methods development
Canadian institutionsnot available
FundersAlzahra University
KeywordsChemistryChromatographyExtraction (chemistry)RepeatabilityAqueous solutionDetection limitMembraneSolventSample preparationDerivatizationHigh-performance liquid chromatographyAnalytical Chemistry (journal)Organic chemistry

Abstract

fetched live from OpenAlex

Recently, electro-assisted extraction of ionic drugs from biological fluids through a supported liquid membrane and into an aqueous acceptor solution was introduced as a new sample preparation technique and has been termed electromembrane extraction (EME). In the present work, this microextraction technique combined with high-performance liquid chromatography and ultraviolet detection has been developed for detection of phenazopyridine (PP) as a local analgesic drug in human plasma and urine samples. From a 6.5 mL neutral aqueous sample, PP was extracted for 20 min through a thin supported liquid membrane of 2-nitrophenyl octyl ether sustained in the pores of the wall of a porous hollow fiber and into an aqueous acidic acceptor solution (25 μL, containing negative electrode) by application of a DC electrical potential. The effects of several factors, including the nature of organic solvent, HCl concentration in donor and acceptor solutions, stirring speed, extraction time, and applied voltage on the extraction efficiency of the drug, were investigated and optimized. Satisfactory linearity ranges with correlation coefficients higher than 0.996 in different extraction media, admissible limits of detection (0.5 and 1.0 ng mL−1 in urine and plasma samples, respectively) and good repeatability and reproducibility (intra- and inter-assay precisions ranged between 3.7%–6.8% and 8.8%–12.5%, respectively) were obtained. The optimized EME procedure was applied to determine the concentration of PP in various matrices, such as plasma and urine samples, and satisfactory results were obtained.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.269
Teacher spread0.242 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueCanadian Journal of ChemistrySame topicAnalytical chemistry methods developmentFrench-language works237,207