MétaCan
Menu
Back to cohort
Record W2016697944 · doi:10.1016/j.carj.2009.02.036

Parallel Imaging Artifacts in Body Magnetic Resonance Imaging

2009· review· en· W2016697944 on OpenAlexaff
Patricia Noël, Roland Bammer, Caroline Reinhold, Masoom A. Haider

Bibliographic record

VenueCanadian Association of Radiologists Journal · 2009
Typereview
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsUniversity of TorontoUniversity Health NetworkHôtel-Dieu de QuébecMcGill UniversityMontreal General HospitalUniversité LavalMount Sinai Hospital
FundersNational Institute of Biomedical Imaging and Bioengineering
KeywordsImage qualityMagnetic resonance imagingMedicineComputer scienceImage resolutionComputer visionArtificial intelligenceImage (mathematics)Radiology

Abstract

fetched live from OpenAlex

OBJECTIVE: To familiarize the reader with the fundamental concepts of partial parallel imaging (PPI); to review the technical aspects of PPI including calibration scan, coil geometry, and field of view (FOV); and to illustrate artifacts related to parallel imaging and describe solutions to minimize their negative impact. RESULTS: PPI has led to a significant advance in body magnetic resonance imaging by reducing the time required to generate an image without loss of spatial resolution. Although PPI can improve image quality, it is not free of artifacts, which can result in significant image degradation. Knowledge of these artifacts and how to minimize their effect is important to optimize the use of parallel imaging for specific body magnetic resonance imaging applications. CONCLUSIONS: The reader will be introduced to the fundamental principles of PPI. Common imaging characteristics of PPI artifacts will be displayed with an emphasis on those seen with image-based methods, the principles behind their generation presented, and measures to minimize their negative impact will be proposed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.985
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.334
Teacher spread0.310 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations28
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueCanadian Association of Radiologists JournalSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207