MétaCan
Menu
Back to cohort
Record W2016846639 · doi:10.1002/anie.201205575

Real‐Time Monitoring of Protein Conformational Dynamics in Solution Using Kinetic Capillary Electrophoresis

2012· article· en· W2016846639 on OpenAlexaff
Christopher M. Clouthier, Gleb G. Mironov, Victor Okhonin, Maxim V. Berezovski, Jeffrey W. Keillor

Bibliographic record

VenueAngewandte Chemie International Edition · 2012
Typearticle
Languageen
FieldEngineering
TopicMicrofluidic and Capillary Electrophoresis Applications
Canadian institutionsUniversity of Ottawa
Fundersnot available
KeywordsElectropherogramCapillary electrophoresisChemistryConformational isomerismKinetic energyKineticsLigand (biochemistry)Conformational changeChromatographyStereochemistryMoleculeBiochemistryOrganic chemistry

Abstract

fetched live from OpenAlex

Conformational analysis: Capillary electrophoresis (CE) allows for the rapid separation of slowly interconverting protein conformers. Kinetic analysis (k(open), k(closed), and K(d)) of electropherograms in the presence and absence of effector ligands allows the measurement of kinetic and thermodynamic constants associated with conformational changes and ligand binding.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.009
Threshold uncertainty score0.620

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.225
Teacher spread0.216 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations42
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueAngewandte Chemie International EditionSame topicMicrofluidic and Capillary Electrophoresis ApplicationsFrench-language works237,207