MétaCan
Menu
Back to cohort
Record W2016926733 · doi:10.1260/2040-2317.2.3.155

Unbonded Post Tensioned Concrete Slabs in Fire - Part II - Modelling Tendon Response and the Consequences of Localized Heating

2011· article· en· W2016926733 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

fundA Canadian funder is recorded on the work.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueJournal of Structural Fire Engineering · 2011
Typearticle
Languageen
FieldEngineering
TopicFire effects on concrete materials
Canadian institutionsnot available
FundersEngineering and Physical Sciences Research CouncilNatural Sciences and Engineering Research Council of CanadaQueen's UniversityRoyal Academy of Engineering
KeywordsStructural engineeringTendonCurrent (fluid)Fire testTransient (computer programming)Relaxation (psychology)Fire safetyEngineeringComputer scienceCivil engineeringElectrical engineering

Abstract

fetched live from OpenAlex

This is Part II of a two part paper dealing with the current state of knowledge of the fire-safe structural design and construction of unbonded post-tensioned (UPT) flat plate concrete structures. Part I provided detailed results of nineteen transient high temperature stress relaxation tests on restrained UPT tendons of realistic length and parabolic longitudinal profiles. Experimentation identified several credible concerns for UPT concrete structures in fire, most notably the potential for premature tendon rupture due to localized heating, which may result from a number of possible causes in a real structure. The real world response of continuous UPT tendons both during and after heating is largely unknown, and is dependent on factors which are not currently accounted for either in standard fire tests or by available prescriptive design guidance. This second part of the paper presents and applies a numerical model to predict the time-temperaturestress-strength interdependencies of stressed UPT tendons under localized transient heating, as may be experienced by tendons in a real concrete building in a real fire. The model is used, along with previously developed and validated computational models for heat transfer and prestress relaxation in UPT tendons, to assess existing prescriptive concrete cover requirements for UPT slabs. It is shown that localized heating of UPT tendons is likely to induce premature tendon rupture during fire, and that current prescriptive code procedures based on concrete cover alone are, in general, insufficient to prevent this. Based on the data presented it appears that minimum code prescribed concrete covers for UPT structures require revision if premature tendon rupture during fire is to be avoided.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.590
Threshold uncertainty score0.743

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.194
Teacher spread0.182 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it