Immediate and Early Loading of Oxidized Tapered Implants in the Partially Edentulous Maxilla: A 1‐Year Prospective Clinical, Radiographic, and Resonance Frequency Analysis Study
Bibliographic record
Abstract
BACKGROUND: The use of immediate/early implant loading protocols offers obvious advantages for the patient. Although well documented in the totally edentulous mandible, information about clinical outcomes from such protocols in the partially edentate maxilla is lacking. PURPOSE: The present study was conducted to clinically and radiographically evaluate a tapered implant design with an oxidized surface for immediate/early loading in the partially edentulous maxilla. The aim was also to correlate implant stability measurements using resonance frequency analysis (RFA) with implant diameter and length, bone quality and quantity, and marginal bone levels and marginal bone loss. MATERIALS AND METHODS: A total of 32 patients with a need of implant treatment in their partially edentulous maxilla were included in the study. A total of 53 Replace Select TiUnite implants (Nobel Biocare AB, Göteborg, Sweden) were used in the study; 16 for single tooth replacements in 16 patients and 37 implants for partial bridges in another 16 patients. The single tooth replacements were loaded the same day with a temporary crown, while permanent partial bridges were delivered within 16 days. Intraoral radiographs were taken at surgery and after 1 year for marginal bone measurements. RFA measurements were performed at baseline and after 3, 6, and 12 months. RESULTS: One implant used for a single tooth replacement failed, giving an overall survival rate of 98.1% after 1 year. On average, 1.1 mm (SD 1.0) bone was lost during 1 year; 1.5 mm (SD 1.0) in single tooth and 0.9 mm (SD 1.0) in partial cases. The implant stability increased with time from 63.3 implant stability quotient (ISQ) (SD 6.1) at baseline to 64.3 (SD 5.3), 65.0 (SD 4.6), and 66.8 (SD 5.6) after 3, 6, and 12 months, respectively. The average change from baseline to 1 year was 3.3 ISQ (SD 5.0) and was statistically significant (p < .05). There was no difference between single and partial cases. Implant stability correlated with bone quantity and quality at implant sites, but not with marginal bone level measurements. CONCLUSIONS: It is concluded that immediate/early loading can be used in the partially edentulous maxilla with good clinical and radiographic short-term outcomes. Implant stability at placement correlated with bone quantity and quality, and increased with time as measured with RFA, indicating a favorable bone tissue response to the loaded implants. Any correlations between RFA and marginal bone level measurements were not observed in the present study.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.002 |
| Meta-epidemiology (narrow) | 0.001 | 0.001 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.001 | 0.001 |
| Scholarly communication | 0.001 | 0.000 |
| Open science | 0.000 | 0.001 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".