MétaCan
Menu
Back to cohort
Record W2017810925 · doi:10.1117/12.844080

Multi-slice to volume registration of ultrasound data to a statistical atlas of human pelvis

2010· article· en· W2017810925 on OpenAlexafffund
Sahar Ghanavati, Parvin Mousavi, Gábor Fichtinger, Pezhman Foroughi, Purang Abolmaesumi

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2010
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsUniversity of British ColumbiaQueen's University
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health ResearchJohns Hopkins University
KeywordsComputer scienceImage registrationArtificial intelligenceComputer visionAtlas (anatomy)Orientation (vector space)FluoroscopyUltrasoundPelvisData setCadaverMedicineRadiologyAnatomyMathematicsImage (mathematics)

Abstract

fetched live from OpenAlex

Identifying the proper orientation of the pelvis is a critical step in accurate placement of the femur prosthesis in the acetabulum in Total Hip Replacement (THR) surgeries. The general approach to localize the orientation of the pelvis coordinate system is to use X-ray fluoroscopy to guide the procedure. An alternative can be employing intra-operative ultrasound (US) imaging with pre-operative CT scan or fluoroscopy imaging. In this paper, we propose to replace the need of pre-operative imaging by using a statistical shape model of the pelvis, constructed from several CT images. We then propose an automatic deformable intensity-based registration of the anatomical atlas to a sparse set of 2D ultrasound images of the pelvis in order to localize its anatomical coordinate system. In this registration technique, we first extract a set of 2D slices from a single instance of the pelvic atlas. Each individual 2D slice is generated based on the location of a corresponding 2D ultrasound image. Next, we create simulated ultrasound images out of the 2D atlas slices and calculate a similarity metric between the simulated images and the actual ultrasound images. The similarity metric guides an optimizer to generate an instance of the atlas that best matches the ultrasound data. We demonstrated the feasibility of our proposed approach on two male human cadaver data. The registration was able to localize a patient-specific pelvic coordinate system with origin translation error of 2 mm and 3.45 mm, and average axes rotation error of 3.5 degrees and 3.9 degrees for the two cadavers, respectively.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.333
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.269
Teacher spread0.250 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2010
Admission routes2
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicAdvanced X-ray and CT ImagingFrench-language works237,207