MétaCan
Menu
← Back to cohort
Record W2018798917 · doi:10.1118/1.2244669

Sci‐Fri AM General‐04: High Contrast Imaging Using Orthogonal Bremsstrahlung Beams: An Experimental Study of Radiation Quality

2006· article· en· W2018798917 on OpenAlexaff
Arman Sarfehnia, Keyvan Jabbari, Jan Seuntjens, E. B. Podgoršak

Bibliographic record

VenueMedical Physics · 2006
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsMcGill University Health Centre
Fundersnot available
KeywordsBremsstrahlungPhotonOpticsPhysicsLinear particle acceleratorCathode rayAttenuationElectronBeam (structure)RadiationPhoton energyMonte Carlo methodMaterials scienceNuclear physicsMathematics

Abstract

fetched live from OpenAlex

Since portal images are created by megavoltage, forward‐directed bremsstrahlung beams, their image quality is inferior to that of images produced by kilovoltage beams. In this study, characteristics of orthogonal bremsstrahlung photons produced by megavoltage electron pencil beams were studied and suitability of their use for improved radiotherapy imaging was evaluated. A 10 MeV electron beam emerging through the research port of a Varian Clinac‐18 linac was made to strike targets of carbon, aluminum and copper. PDD and attenuation measurements of both the forward and orthogonal beams were performed, and experimental results were compared with Monte Carlo‐calculated findings. Images of contrast objects were acquired with Agfa 400 diagnostic films and their contrast levels were analyzed. Photon yield and effective energy are lower for orthogonal beams than for forward beams, and the differences are more pronounced for targets of lower atomic number. The effective energy of a spectrum produced by carbon dropped by a factor of 10 from 1535 keV in the forward direction to 151 keV in the orthogonal direction, while for aluminum the effective energy dropped by 77% to 425 keV, and for copper by 37% to 1107 keV. The image contrast of films exposed with orthogonal beams was qualitatively determined to be superior to that obtained using the forward megavoltage beams. Using their relatively low effective energy, orthogonal bremsstrahlung beams produced by megavoltage electrons striking low atomic number targets yield images with a higher contrast than do forward bremsstrahlung beams.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.013
Threshold uncertainty score0.043

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0130.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.339
Teacher spread0.323 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueMedical Physics→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→