MétaCan
Menu
Back to cohort
Record W2019054294 · doi:10.1117/12.2082020

Apodized-aperture pixel design to increase high-frequency DQE and reduce noise aliasing in x-ray detectors

2015· article· en· W2019054294 on OpenAlexaff
Elina Ismailova, Karim Karim, Ian A. Cunningham

Bibliographic record

VenueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2015
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsUniversity of WaterlooWestern University
Fundersnot available
KeywordsDetective quantum efficiencyDetectorDot pitchOpticsImage sensorX-ray detectorPixelImage qualitySpatial frequencyOptical transfer functionImage resolutionNoise (video)Aperture (computer memory)PhysicsAliasingComputer scienceComputer visionImage (mathematics)AcousticsFilter (signal processing)

Abstract

fetched live from OpenAlex

The detective quantum efficiency (DQE) of an x-ray detector, expressed as a function of spatial frequency, describes the ability to produce high-quality images relative to an ideal detector. While the DQE normally decreases substantially with increasing frequency, we describe an approach that can be used to improve the DQE response by increasing the DQE at high spatial frequencies. The approach makes use of an apodized-aperture pixel (AAP) design that requires use of a high-resolution x-ray converter such as selenium coupled to a sensor array with very small physical sensor elements, such as CMOS sensors. While sensors with elements of 10 - 25 μm are too small for most practical applications in medical radiography, we describe how larger image pixels of a practical size can be synthesized to provide a better DQE than simple binning or using physical pixels of the same size. A theoretical cascaded-systems analysis shows the DQE at the image sampling cut-off frequency can be improved by up to a factor of 2.5x. The AAP approach was validated experimentally using a CMOS/CsI-based detector having 0.05-mm sensor elements. Using AAP images with 0.2-mm pixels, the high-frequency DQE value was increased from 0.2 to 0.4 compared to simple 4x4 binning. It is concluded that ultra-high-resolution sensors can be used to optimize the high-frequency performance of x-ray detectors and make substantial improvements in image quality for visualization of small stuctures and fine image detail in comparison to current imaging systems.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.294
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.229
Teacher spread0.215 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIESame topicAdvanced X-ray and CT ImagingFrench-language works237,207