MétaCan
Menu
Back to cohort
Record W2019575010 · doi:10.1021/bc0155871

Profiling Solid-Phase Synthesis Products by Free-Solution Conjugate Capillary Electrophoresis

2002· article· en· W2019575010 on OpenAlexaff
Wyatt N. Vreeland, Gary W. Slater, Annelise E. Barron

Bibliographic record

VenueBioconjugate Chemistry · 2002
Typearticle
Languageen
FieldEngineering
TopicMicrofluidic and Capillary Electrophoresis Applications
Canadian institutionsUniversity of Ottawa
FundersNational Institute of General Medical Sciences
KeywordsChemistryCapillary electrophoresisChromatographyHigh-performance liquid chromatographyConjugateOligomerSolid phase extractionElectrophoresisBioconjugationCombinatorial chemistryOrganic chemistry

Abstract

fetched live from OpenAlex

Solid-phase synthesis of oligomers, both natural and nonnatural, has proved to be invaluable for the development of many areas of biotechnology. A critical step in the solid-phase synthesis of any oligomer is determining the number and concentration of different constituents present in the product mixture resulting from the synthesis, both before and after purification. Most typically, this analysis is performed by reversed-phase high performance liquid chromatography (RP-HPLC), with the separated components detected by UV absorbance. Recently, we described a novel technique, free-solution conjugate electrophoresis (FSCE), for the high-resolution separation and sensitive laser-induced fluorescence (LIF) detection of uncharged, synthetic polymers, PEG in particular. In this report, we apply this bioconjugate capillary electrophoresis technique to analyze products of the solid-phase synthesis of oligomeric polyamides, namely poly(N-substituted glycines), or polypeptoids. When compared to more traditional RP-HPLC analysis, FSCE analysis of oligomeric peptoids results in separation resolutions that are approximately five times higher and separation efficiencies that are increased by 150%. Moreover, when FSCE with LIF detection is applied to the analysis of oligomeric polyamides after HPLC purification, impurities that are not detectable in RP-HPLC analysis are readily separated and detected. With the advent of capillary array electrophoresis (CAE), which allows for automated, parallel analysis of many different samples, we believe that FSCE will be especially applicable to the analysis of combinatorial synthesis products, by allowing researchers to evaluate many different samples in a single, highly parallel, fully automated analysis. This is in contrast to RP-HPLC analysis, in which samples must be analyzed in series.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.213
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.219
Teacher spread0.210 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations25
Published2002
Admission routes1
Has abstractyes

Explore more

Same venueBioconjugate ChemistrySame topicMicrofluidic and Capillary Electrophoresis ApplicationsFrench-language works237,207