MétaCan
Menu
Back to cohort
Record W2019934405 · doi:10.1118/1.1589493

Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. II. The effect of a finite number of fractions

2003· article· en· W2019934405 on OpenAlexaff
Tim Craig, Jerry Battista, Jake Van Dyk

Bibliographic record

VenueMedical Physics · 2003
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsWestern University
Fundersnot available
KeywordsConvolution (computer science)Imaging phantomMathematicsDosimetryRange (aeronautics)AlgorithmApplied mathematicsNuclear medicineComputer scienceMaterials scienceArtificial intelligence

Abstract

fetched live from OpenAlex

Convolution methods can be used to model the effect of geometric uncertainties on the planned dose distribution in radiation therapy. This requires several assumptions, including that the patient is treated with an infinite number of fractions, each delivering an infinitesimally small dose. The error resulting from this assumption has not been thoroughly quantified. This is investigated by comparing dose distributions calculated using the Convolution method with the result of Stochastic simulations of the treatment. Additionally, the dose calculated using the conventional Static method, a Corrected Convolution method, and a Direct Simulation are compared to the Stochastic result. This analysis is performed for single beam, parallel opposed pair, and four-field box techniques in a cubic water phantom. Treatment plans for a simple and a complex idealized anatomy were similarly analyzed. The average maximum error using the Static method for a 30 fraction simulation for the three techniques in phantoms was 23%, 11% for Convolution, 10% for Corrected Convolution, and 10% for Direct Simulation. In the two anatomical examples, the mean error in tumor control probability for Static and Convolution methods was 7% and 2%, respectively, of the result with no uncertainty, and 35% and 9%, respectively, for normal tissue complication probabilities. Convolution provides superior estimates of the delivered dose when compared to the Static method. In the range of fractions used clinically, considerable dosimetric variations will exist solely because of the random nature of the geometric uncertainties. However, the effect of finite fractionation appears to have a greater impact on the dose distribution than plan evaluation parameters.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.020
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.010
Threshold uncertainty score0.033

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.020
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.002
Open science0.0020.002
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.343
Teacher spread0.309 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations52
Published2003
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207