MétaCan
Menu
Back to cohort
Record W2020438623 · doi:10.1097/icl.0b013e3181ac4a8d

Patient and Practitioner Compliance With Silicone Hydrogel and Daily Disposable Lens Replacement in the United States

2009· article· en· W2020438623 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueEye & Contact Lens Science & Clinical Practice · 2009
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsSilicone hydrogelDemographicsMedicineLens (geology)SiliconeCompliance (psychology)Family medicineContact lensOphthalmologyPsychologyDemographyMaterials scienceEngineering

Abstract

fetched live from OpenAlex

OBJECTIVE: The objectives of this study were to assess current recommendations for replacement frequency (RF) of silicone hydrogel (SH) and daily disposable (DD) lenses, to determine compliance with these recommendations, and to investigate the reasons given for noncompliance. METHODS: A package containing 20 patient surveys was sent to 309 eye care practitioners (ECPs) in the United States who had agreed to participate in the study. One thousand eight hundred fifty-nine completed surveys were received from 158 ECPs and 1,654 surveys were eligible for analysis. Questions related to patient demographics, lens type, lens wearing patterns, the ECP instructions for RF, and the actual patient reported RF. ECPs were asked to provide lens information and their recommendation for RF after the surveys had been completed and sealed in envelopes. All responses were anonymous. RESULTS: Sixty-six percent of patients were women and their mean age was 34 +/- 12 years. Eighty-eight percent of lenses were worn for daily wear, 12.8 +/- 3.2 hours a day, 6.2 +/- 1.5 days a week. Lens type distribution was 16% DD, 45% 2 week (2W) SH, and 39% 1 month (1M) SH. ECP recommendations for RF varied according to the lens type; 1% of 1M (95% CI 0.2-1.7), 4% of DD (95% CI 2.1-7.2), and 18% of 2W (95% CI 15.1-20.7) patients were given instructions that did not conform to the manufacturers' recommended RF (MRRF). When considering only those patients who were given the correct instructions for RF, 38% were not compliant with the MRRF; noncompliance rates varied according to the lens type and were 12% for DD (95% CI 8.6-17.2), 28% for 1M (95% CI 24.9-32.1), and 52% for 2W (95% CI 47.8-55.8). The most frequent reasons for over wearing lenses were "forgetting which day to replace lenses" (51%) and "to save money" (26%). Fifty-three percent believed that a reminder system would aid compliance; the most popular methods being a cell phone reminder or text message (29%) and a nominated day each week or month (26%). Discussions between the ECPs and the patients were more extensive for patients who were compliant with the MRRF. CONCLUSIONS: ECPs recommended RFs more frequently with DD and 1M SH lenses than with 2W SH lenses, consistent with manufacturers' recommendations. Patients were less compliant with RF than ECPs for all lens types investigated. Patients were most compliant with RF when wearing DD lenses and least compliant when wearing 2W SH lenses. Better communication facilitated greater compliance with RF. More than half of those not replacing lenses, when recommended, reported that this was because they forgot which day to replace their lenses.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.003
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.137
Threshold uncertainty score0.666

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.002
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.047
GPT teacher head0.368
Teacher spread0.321 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it