MétaCan
Menu
Back to cohort
Record W2020683193 · doi:10.4236/abb.2013.46094

Preliminary study of binary protein adsorption system and potential bioseparation under homogeneous field of shear in airlift biocontactor

2013· article· en· W2020683193 on OpenAlexafffund
Yaser Dahman, Kithsiri E. Jayasuriya

Bibliographic record

VenueAdvances in Bioscience and Biotechnology · 2013
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicProtein purification and stability
Canadian institutionsToronto Metropolitan University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsAdsorptionBovine serum albuminChemistryChromatographyPulmonary surfactantProtein adsorptionGlobular proteinChemical engineeringOrganic chemistryCrystallographyBiochemistry

Abstract

fetched live from OpenAlex

This paper investigates the bioseparation of binary protein mixtures using polystyrene based anion exchange resin. Adsorption experiments were conducted in batch mode using draft-tube internally recirculate dair lift biocontactor in comparison with the conventional shake flask batch adsorption equilibrium experiments. Binary protein mixtures contained bovine serum albumin (BSA) and bovine haemoglobin (BHb) at different initial fractions. Results from single solute adsorption experiments in biocontactor showed that both proteins were equally adsorbed onto the resin with equilibrium reached in an equal time period. This represents similar affinities towards the negatively charged resin surface, although BSA was expected to adsorb through specific forces. Adsorption results showed that BSA has hindered the BHb adsorption in the biocontactor, although adsorption of both proteins was equally hindered in the shake flasks adsorption experiments. Moreover, adsorption of BHb was inhibited up to 29% in the presence of BSA compared to the adsorption of BHb from a solution containing single solute of BHb at the same initial concentration. Similarly, the presence of BHb has hindered the adsorption of BSA by 59%. Adsorptions of both BSA and BHb from binary solution when each formed 75% initial fraction while the other protein formed the remaining 25% were relatively low with equilibrium reached in shorter time. Moreover, considerable amount of proteins remained in the solution, which demonstrates that multilayer adsorption most likely didn’t occur at the relatively small protein concentrations used in the present study. In general, the higher adsorption of BHb can also be related to the compressibility of its molecules which allowed for higher adsorption capacity. The homogeneous and lower shear environment in the airlift biocontactor compared to the other conventional batch adsorption in shake flask reduced the compressibility of BHb that caused higher BSA adsorption from binary solutions of BSA and BHb, which allowed for better bioseparation of both proteins.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.082
Threshold uncertainty score0.305

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.005
GPT teacher head0.253
Teacher spread0.247 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2013
Admission routes2
Has abstractyes

Explore more

Same venueAdvances in Bioscience and BiotechnologySame topicProtein purification and stabilityFrench-language works237,207