MétaCan
Menu
Back to cohort

Maintenance of asthma control by once‐daily inhaled ciclesonide in adults with persistent asthma

2004· article· en· W2021754976 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueAllergy · 2004
Typearticle
Languageen
FieldMedicine
TopicAsthma and respiratory diseases
Canadian institutionsInstitut universitaire de cardiologie et de pneumologie de QuébecLakeridge HealthUniversité LavalRegional Municipality of NiagaraToronto Western HospitalUniversity Health Network
Fundersnot available
KeywordsCiclesonideMedicinePlaceboMorningAsthmaEveningSpirometryAnesthesiaInternal medicineInhaled corticosteroids

Abstract

fetched live from OpenAlex

BACKGROUND: Inhaled corticosteroids (ICS) are recommended therapy for persistent asthma, although side effects can limit appropriate use. Ciclesonide, a novel ICS, is activated in the lung, thereby reducing systemic activity and side effects. This 12-week, double-blind, randomized, parallel-group, placebo-controlled study evaluated the efficacy and safety of ciclesonide in adults with persistent asthma. METHODS: After a 2-week baseline period in which current ICS treatment was continued, 329 patients were randomized to receive ciclesonide 160 microg (n = 107) or 640 microg (n = 112) (ex-actuator doses, equivalent to 200 and 800 microg ex-valve, respectively), or placebo (n = 110) once daily in the morning. Efficacy was monitored by asthma symptom scores, rescue medication use, morning and evening peak expiratory flow (PEF) measurements, spirometry, and probability of study completion without experiencing lack of efficacy. RESULTS: Morning PEF remained stable with either ciclesonide dose but decreased with placebo; the differences were significant (P < 0.0001) for both ciclesonide doses vs placebo. The forced expiratory volume in 1 s and forced vital capacity decreased significantly with placebo (P < 0.005), but were unchanged with ciclesonide. Lack of efficacy was significantly greater for patients switched to placebo (63%) than it was for those treated with ciclesonide 160 microg (30%) (P < 0.0001 vs placebo) or ciclesonide 640 microg (31%) (P < 0.0001 vs placebo). There were no significant differences between the two tested doses of ciclesonide with respect to efficacy and safety. Serum and 24-h urine cortisol were unaffected by ciclesonide treatment. Both doses of ciclesonide were well tolerated with no cases of oral candidiasis. CONCLUSION: Ciclesonide (160 or 640 microg) once daily in the morning effectively maintains asthma control, does not affect cortisol levels, and has an adverse event profile comparable with placebo in adults with primarily mild to moderate asthma.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.303
Threshold uncertainty score0.576

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.208
Teacher spread0.203 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it